The TELE System YM101 Portable Pulse Oximeter is a non-invasive device designed for spot-checking arterial hemoglobin oxygen saturation (SpO2) and pulse rate (PR) in adults and pediatric patients at home or in clinical settings. It also indicates the Perfusion Index (PI). This device is simple to operate and provides quick, reliable measurements.

The YM101 is particularly useful for individuals with conditions such as asthma, chronic bronchitis, COPD, or pneumonia, or simply for monitoring blood oxygen levels in patients experiencing fever, cough, or shortness of breath. This pulse oximeter is a certified medical device.

2. Enfòmasyon sou Sekirite

  • Li tout enstriksyon ak anpil atansyon anvan ou itilize.
  • This device is intended for non-invasive spot-checking of SpO2 and pulse rate. It is not intended for continuous monitoring.
  • Consult a medical professional for interpretation of results. Self-diagnosis and self-treatment based on measurements can be dangerous.
  • Pa sèvi ak aparèy la nan yon anviwònman MRI oswa CT.
  • Kenbe aparèy la lwen dlo ak imidite.
  • Do not use the device on the same finger for more than 5 minutes to avoid discomfort or injury due to prolonged pressure.
  • Kenbe soti nan atenn timoun yo.

3. Pwodwi konpozan

The TELE System YM101 Pulse Oximeter consists of several key components:

  • 1.5" LED Display: Shows SpO2, pulse rate, perfusion index, and bar graph.
  • bouton: For power on/off and display mode changes.
  • Capteur: Integrated infrared sensor for measurement.
  • MCU (Microcontroller Unit): Processes data.
  • Kouvèti batri: Pwoteje konpatiman batri a.
Eksploze view of the TELE System YM101 Pulse Oximeter showing its internal components: 1.5 inch LED display, button, sensor, MCU, and battery cover.

Figi 3.1: Eksploze view of the YM101 Pulse Oximeter components.

4. Enstalasyon

Anvan premye itilizasyon an, enstale pil yo:

  1. Open the battery cover located at the back of the device.
  2. Insert two (2) AAAA batteries according to the polarity indicators (+/-) inside the compartment. Note: Batteries are not included with the device.
  3. Fèmen kouvèti batri a byen.
Side view of the TELE System YM101 Pulse Oximeter, showing the battery compartment area.

Figi 4.1: Side view of the YM101 Pulse Oximeter.

5. Operasyon Enstriksyon

Swiv etap sa yo pou pran yon mezi:

  1. Ensure the device has batteries installed.
  2. Louvri cl laamp oksimèt batman kè a.
  3. Insert one of your fingers (preferably the index finger) into the rubber opening of the oximeter, ensuring the nail is facing upwards towards the display.
  4. Lage clamp. The device will automatically power on and begin measurement.
  5. Keep your hand still during the measurement. The display will show your SpO2 percentage, pulse rate (BPM/PR), and Perfusion Index (PI). A bar graph will also indicate pulse intensity.
  6. To change the display orientation or brightness, briefly press the power button while the device is on. The 1.5" LED display offers 3 levels of brightness.
  7. The device can be set to alarm if SpO2 or bpmPR limits are exceeded. Refer to the full manual for alarm setting details.
  8. Remove your finger from the device. The oximeter will automatically power off after a few seconds of inactivity.
A finger inserted into the TELE System YM101 Pulse Oximeter, with the LED display showing SpO2 at 98%, BPM/PR at 79, and PI at 20.0%.

Figure 5.1: YM101 Pulse Oximeter in use, displaying readings.

The open clamp of the TELE System YM101 Pulse Oximeter, showing the internal infrared sensor.

Figi 5.2: Entèn view of the YM101 Pulse Oximeter sensor.

6. Antretyen

  • Netwayaj: Siye aparèy la ak yon twal mou dampened with alcohol (70% ethanol or isopropanol) before and after each use. Do not immerse the device in liquid.
  • Depo: Store the oximeter in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Ranplasman batri: Ranplase pil yo lè endikatè pil fèb la parèt sou ekran an. Retire pil yo si ou p ap itilize aparèy la pou yon peryòd tan pwolonje.
  • Dispozisyon: Dispose of the device and batteries according to local environmental regulations.

NAN. Depanaj

PwoblèmKòz posibSolisyon
No display after pressing power buttonPil yo mouri oswa yo pa byen mete.Ranplase pil yo oubyen mete yo ankò avèk polarite ki kòrèk la.
Lekti ki pa egzak oswa ki pa estabFinger not inserted properly; patient movement; cold finger; nail polish.Reinsert finger correctly; remain still; warm the finger; remove nail polish.
"Finger Out" messageFinger not detected or removed.Insert finger fully into the device.

8. Espesifikasyon

  • Mak: Sistèm TELE
  • Modèl: YM101
  • Ekspozisyon: 1.5" LED, 3 brightness levels
  • Ranje mezi: SpO2: 70-100%
  • Presizyon: SpO2: ±1% / Pulse Rate: ±1 bpm
  • Indications/Measurements: SpO2%, Heart Rate (BPM/PR), Perfusion Index (PI), Bar Graph
  • Sous pouvwa: 2 x AAAA batteries (not included)
  • Koulè: Blan
  • Dimansyon: Approximately 57mm (Length) x 31mm (Width)
  • Referans manifakti: 96010001
  • Peyi orijin: Lachin
Top-desann view of the TELE System YM101 Pulse Oximeter, showing its dimensions: 57mm in length and 31mm in width.

Figure 8.1: Dimensions of the YM101 Pulse Oximeter.

9. Garanti ak sipò

For warranty information, technical support, or service inquiries regarding your TELE System YM101 Pulse Oximeter, please refer to the warranty card included in your product packaging or visit the official TELE System website. You may also contact TELE System customer service directly for assistance.