DAB FEKA600

Manyèl Itilizatè Ponp Submersible DAB FEKA 600 MA

Model: FEKA600

1. Entwodiksyon

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your DAB FEKA 600 MA submersible pump. Please read this manual thoroughly before using the pump and keep it for future reference.

The DAB FEKA 600 MA is a robust submersible pump designed for draining and lifting light wastewater, greywater, and rainwater in domestic and residential environments. It is suitable for both fixed and mobile installations.

2. Enfòmasyon sou Sekirite

Always observe the following safety precautions to prevent personal injury and damage to the pump.

  • Sekirite elektrik: Ensure the power supply matches the pump's specifications. Always disconnect power before performing any maintenance or installation. Do not operate the pump with a damaged power cord.
  • Sekirite dlo: Never touch the pump or the water it is pumping while it is connected to power. This pump is designed for water only; do not use it for flammable, corrosive, or explosive liquids.
  • Enstalasyon: Install the pump in a well-ventilated area. Ensure the pump is stable and cannot tip over. Do not lift the pump by its power cable.
  • Timoun ak bèt kay: Kenbe timoun ak bèt kay lwen ponp lan ak zòn kote l ap fonksyone a.
  • Antretyen: Only qualified personnel should perform repairs. Use only genuine replacement parts.

3. Pwodwi souview

The DAB FEKA 600 MA pump is engineered for reliability and durability, featuring high-quality materials and a robust design.

DAB FEKA 600 MA Submersible Pump

Figure 3.1: DAB FEKA 600 MA Submersible Pump - Front View.

DAB FEKA 600 MA Pump Features Diagram

Figure 3.2: Key Features of the DAB FEKA 600 MA Pump. This diagram highlights the automatic start/stop float arm, durable construction materials, a flow rate of 15,000 liters per hour, a maximum head of 9 meters, and the ability to handle solids up to 25mm. Note: Official specifications for flow rate and head are provided in Section 8.

3.1 Konpozan kle

  • Kò ponp: Constructed from technopolymer for durability.
  • Suction Grille: Designed for efficient intake and handling of solids.
  • Motè: Asynchronous submersible motor for continuous duty, with integrated thermal protection for single-phase versions. Made of AISI 304 stainless steel with an AISI 431 steel shaft for corrosion resistance.
  • Flote switch: Integrated float switch for automatic operation (in automatic versions).
  • Triple Seal System: Oil bath triple seal for enhanced reliability.

3.2 Aplikasyon

The FEKA 600 MA pump is suitable for various applications, including:

DAB FEKA 600 MA Pump Applications

Figure 3.3: Common Applications for the DAB FEKA 600 MA Pump. This image illustrates its use for emptying crawl spaces, pumping dirty water, dewatering construction sites, and managing rainwater.

  • Draining crawl spaces
  • Pumping dirty water and greywater
  • Dewatering construction sites
  • Managing rainwater

4. Enstalasyon ak Enstalasyon

Bon enstalasyon enpòtan anpil pou pèfòmans ak lonjevite ponp lan. Swiv etap sa yo ak anpil atansyon.

4.1 Lis Enstriksyon Pre-Enstalasyon an

  • Ensure the installation site is clear of debris and has adequate space.
  • Verifye ekipman pou pouvwa a voltage ak frekans lan koresponn ak egzijans ponp lan.
  • Prepare the discharge pipe and any necessary fittings.

4.2 Etap enstalasyon yo

  1. Pozisyonman Ponp lan: Place the pump on a stable, flat surface in the lowest part of the area to be drained. Ensure the suction grille is not obstructed. The minimum admission level is 38 mm.
  2. Connecting the Discharge Pipe: Attach a suitable discharge pipe to the pump's outlet. Ensure all connections are watertight. The pump has a 1 1/4" G threaded outlet.
  3. Float Switch Adjustment (for automatic versions): Adjust the float switch cable length to set the desired ON/OFF levels. Ensure the float can move freely without obstruction.
  4. Koneksyon pouvwa: Connect the pump to a grounded electrical outlet. Ensure the circuit is protected by a residual current device (RCD).
  5. Tès: Before full operation, perform a test run to ensure the pump activates and deactivates correctly and that there are no leaks.

For detailed technical specifications and installation diagrams, refer to the official technical sheet: DAB FEKA Technical Sheet.

5. Operasyon Enstriksyon

The DAB FEKA 600 MA pump is designed for straightforward operation.

5.1 Automatic Operation (with float switch)

  1. Ensure the pump is properly installed and connected to power.
  2. The pump will automatically start when the water level rises and lifts the float switch.
  3. The pump will automatically stop when the water level drops and the float switch returns to its lower position.

5.2 Manual Operation (without float switch or for specific tasks)

For manual versions or when bypassing the float switch:

  1. Connect the pump to power. The pump will begin operating immediately.
  2. Monitor the water level to prevent the pump from running dry for extended periods. The pump can run dry for up to 1 minute without damage.
  3. Disconnect the pump from power to stop operation.

Enpòtan: Do not allow the pump to run dry for more than 1 minute. Prolonged dry running can cause damage.

6. Antretyen

Regular maintenance ensures optimal performance and extends the pump's lifespan. Always disconnect the pump from the power supply before any maintenance.

6.1 Netwayaj Ponp lan

  • Periodically inspect the suction grille for blockages from debris, leaves, or other solids. Clean as necessary.
  • Rinse the pump with clean water after use, especially if pumping heavily contaminated liquids.

6.2 Depo ivè

If the pump will not be used for an extended period or during freezing temperatures:

  • Drain all water from the pump and discharge pipe.
  • Netwaye ponp lan byen.
  • Sere ponp lan nan yon kote ki sèk epi ki pa gen jèl.

6.3 Sèvis Pwofesyonèl

For internal components, motor, or seal inspection, it is recommended to contact a qualified service technician. Do not attempt to disassemble the motor housing.

NAN. Depanaj

Anvan ou kontakte sipò a, review pwoblèm komen sa yo ak solisyon yo.

PwoblèmKòz posibSolisyon
Ponp pa kòmanse.Pa gen ekipman pou pouvwa.
Float switch stuck (automatic version).
Pwoteksyon tèmik surcharge aktive.
Tcheke koneksyon kouran ak disjoncteurs.
Clear any obstructions around the float switch.
Kite ponp lan refwadi; li ta dwe re-kòmanse otomatikman.
Ponp lan ap mache men pa gen dlo k ap soti.Suction grille blocked.
Discharge pipe blocked or kinked.
Air lock in the pump.
Disconnect power and clear the suction grille.
Check and clear the discharge pipe.
Submerge the pump completely and shake gently to release air.
Ponp lan limen epi li etenn souvan.Float switch incorrectly adjusted.
Insufficient water volume.
Adjust float switch to allow for a larger water level differential.
Ensure adequate water volume for continuous operation.
Rediksyon nan to koule.Partial blockage in suction or discharge.
Pump wear.
Clean suction grille and check discharge pipe.
Kontakte pèsonèl sèvis kalifye pou enspeksyon.

8. Espesifikasyon teknik

Detailed specifications for the DAB FEKA 600 MA pump.

ParamètValè
ModèlFEKA 600 MA
Pouvwa0.70 HP
Voltage230 V (2.3E+2 Volts)
Pousantaj maksimòm koule16 m³/h (16,000 liters/hour)
Max tèt7.5 m
Pwofondè Maksimòm Imèsyon7 m
Pumped Liquid TypeWastewater and Rainwater
Free Passage of Solids25 mm
Min Admission Level38 mm
Tanperati Likid Range+0°C to +35°C (domestic use)
+0°C to +50°C (other uses)
Klas pwoteksyonIP 68
MateryèlTechnopolymer body, Stainless Steel motor (AISI 304), Steel shaft (AISI 431)
Dimansyon (apeprè)43.4 x 26 x 19.8 cm (Pakè)
43 x 21 x 29 cm (Pump)
Pwa (apeprè)6.24 kg

For complete technical details, please refer to the official product documentation provided by DAB PUMPS.

9. Garanti ak sipò

Enfòmasyon konsènan garanti pwodwi a ak sipò kliyan.

9.1 Enfòmasyon sou Garanti

Specific warranty terms and conditions are typically provided with your purchase documentation or can be found on the manufacturer's official websit la. Tanpri konsève prèv acha ou a pou reklamasyon garanti.

9.2 Sipò pou Kliyan

For technical assistance, spare parts, or service inquiries, please contact your authorized DAB PUMPS dealer or visit the official DAB PUMPS websit pou enfòmasyon kontak.

Official commercial profile of the Feka range: DAB FEKA Commercial Profile.

© 2025 DAB PUMPS. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.