Gebildet AD16-22D/S

Gebildet AC 110V 22mm LED Pilot Signal Light Instruction Manual

Model: AD16-22D/S

Entwodiksyon

Thank you for choosing the Gebildet AC 110V 22mm LED Pilot Signal Lights. These indicators are designed for clear visual signaling in various electrical equipment, machinery, and control panels. This manual provides essential information for safe installation, operation, and maintenance of your LED signal lights.

A set of Gebildet 22mm LED pilot signal lights in various colors including red, green, blue, white, and yellow.

Image: A collection of Gebildet 22mm LED pilot signal lights, showcasing the available colors: red, green, blue, white, and yellow.

Pwodwi souview

Karakteristik kle

  • Voltage: 110V AC
  • Kouran: 20mA
  • Dyamèt twou monte: 22mm
  • Koulè ki ap dirije: Red, Yellow, Blue, Green (available in various packs)
  • Klate: ≥ 100cd/㎡
  • Mekanik lavi: ≥ 1,000,000 sik
  • Lavi elektrik: ≥ 500,000 sik
  • Tanperati operasyon: -25 ℃ pou +55 ℃
  • Chòk ak Vibration rezistan
  • Materyèl: Plastik dirab
  • Klas pwoteksyon: IP65

Kontni pake

  • 12 x LED Indicator Lights (typically 3 each of Red, Yellow, Blue, Green)
  • Mounting Nuts and Washers (pre-assembled or included for installation)

Enstalasyon ak Enstalasyon

Prekosyon Sekirite

  • Ensure power is disconnected from the circuit before attempting any installation.
  • Se pèsonèl kalifye ki dwe fè enstalasyon an pou evite danje elektrik.
  • Verifye vol ki kòrèk latage (110V AC) before connecting the indicator lights.

Enstriksyon pou monte

  1. Drill a 22mm diameter hole in the desired panel location. The panel thickness should be between 1mm and 4mm.
  2. Insert the LED indicator light into the drilled hole from the front of the panel.
  3. From the rear of the panel, secure the indicator by tightening the provided mounting nut and washer.

Enstriksyon fil elektrik

Connect the two screw terminals located on the back of the indicator to your 110V AC power source. For AC indicators, polarity is generally not critical, but ensure all connections are secure and properly insulated to prevent short circuits.

Demonte view of the LED indicator light showing its components including the main body, lens, mounting nut, washer, and screw terminals.

Image: Disassembled view of the LED indicator light, showing the main body, lens, mounting nut, washer, and screw terminals for electrical connection.

Enstriksyon Operasyon

Operasyon debaz

Once the LED indicator light is correctly installed and wired, it will illuminate when power is supplied to its terminals. The light serves as a clear visual signal for the operational status of the connected circuit or equipment.

Example application of Gebildet LED pilot lights on a control panel, showing red for stop, green for start-up, yellow for model, blue for function, and white for suspend.

Imaj: Egzample application of Gebildet LED pilot lights on a control panel, illustrating their use for various status indications such as 'STOP', 'START-UP', 'FUNCTION', and 'SUSPEND'.

Antretyen

Netwayaj

To maintain optimal visibility, wipe the indicator lens with a soft, dry cloth. Avoid using abrasive cleaners, harsh chemicals, or solvents, as these can damage the plastic material.

Enspeksyon

Periodically inspect the wiring connections to ensure they remain tight and show no signs of wear or corrosion. Also, check that the mounting nut is securely fastened.

Fim Pwoteksyon

The indicator lens may come with a thin protective film. For the clearest display, gently peel this film off before initial use.

Close-up of an LED indicator light showing a protective film being peeled off the lens with a utility knife.

Image: Close-up of an LED indicator light, demonstrating the removal of the protective film from the lens for improved visibility and clarity.

Depanaj

Light Does Not Illuminate

  • Tcheke ekipman pou pouvwa: Ensure that 110V AC power is correctly supplied to the indicator terminals. Use a multimeter to verify voltage si sa nesesè.
  • Tcheke fil elektrik: Verify that all connections are secure and correctly wired according to the installation instructions.
  • Enspekte pou domaj: Visually inspect the indicator for any visible damage to the housing or terminals.

Dim oswa Flickering Limyè

  • Voltage Fluktiyasyon: Ensure a stable 110V AC power source. Unstable voltage can cause inconsistent illumination.
  • Koneksyon ki lach: Re-check all wiring connections to ensure they are tight and making good contact.
Entèn view of an LED indicator light highlighting the voltage stabilizing chip, which ensures stable brightness and longer lifetime.

Imaj: Entèn view of an LED indicator light, pointing out the voltage stabilizing chip responsible for consistent brightness and extended operational life.

Espesifikasyon teknik

Karakteristik Spesifikasyon
ModèlAD16-22D/S
Voltage110V AC
Kouran20mA
Dyamèt twou aliye22mm
Panèl epesè1-4mm
Dirije KoulèRed, Yellow, Blue, Green (R/G/B/Y optional)
Klète≥ 100cd/㎡
Lavi mekanik≥ 1,000,000 sik
Lavi elektrik≥ 500,000 sik
Tanperati Fonksyònman-25 ℃ pou +55 ℃
Total Size (Max.D*H)Approx. 29x51mm (1.14"D x 2.01"H)
MateryèlPlastik
Klas pwoteksyonIP65
Kalite sous limyèLimyè Emisyon Dyòd
Karakteristik espesyalShock & vibration resistant
UPC729257786306
Diagram showing the dimensions of the LED indicator light: 22mm diameter, 48mm height, and 28mm width at the widest point of the cap. Also lists specifications like 110V AC, 20mA, 22mm mounting hole, 1-4mm panel thickness, Model AD16-22DS, Working life >=30000 hours, LED color R/G/B/W/Y optional, Protection class IP65.

Image: Dimensional diagram of the LED indicator light, detailing its physical measurements and key electrical specifications.

Garanti ak sipò

Gebildet products are manufactured to high-quality standards. For any questions, technical assistance, or support regarding your LED Pilot Signal Lights, please contact your retailer or the manufacturer directly. Please retain your proof of purchase for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.