1. Entwodiksyon
Thank you for choosing the Homely M890G Digital Multimeter. This device is a portable, battery-powered digital multimeter designed for measuring AC/DC voltage, AC/DC current, resistance, capacitance, frequency, temperature, diode, and transistor hFE. It features a clear digital display, data hold function, and auto power-off for convenience and efficiency. Please read this manual thoroughly before use to ensure safe and proper operation.
2. Enfòmasyon sou Sekirite
WARNING: To avoid electric shock or personal injury, and to avoid damage to the meter or to the equipment under test, observe the following safety rules:
- Toujou asire w ke mèt la nan fonksyon ak seri ki kòrèk la anvan ou pran mezi.
- Pa aplike plis pase rated voltage, jan yo make sou kontè a, ant tèminal yo oswa ant nenpòt tèminal ak tè tè a.
- Pran anpil prekosyon lè w ap travay ak voltagse pi wo a 60V DC oswa 30V AC RMS. Sa yo voltages poze yon danje chòk.
- Disconnect the test leads from the circuit before changing functions or ranges.
- Pa sèvi ak mèt la si li sanble domaje oswa si izolasyon sou fil tès yo konpwomèt.
- Remove the test leads from the meter before opening the battery cover or fuse cover.
- Ranplase pil la le pli vit ke endikatè pil fèb la parèt pou asire lekti egzak.
- Pa sèvi ak mèt la nan anviwònman ki gen gaz, vapè, oswa pousyè ki ka eksploze.
3. Pake kontni
Verify that all items listed below are present and undamaged:
- Homely M890G Digital Multimeter
- Test Leads (one red, one black)
- K-Type Thermocouple Temperature Probe
- Manyèl itilizatè

Figure 3.1: Contents of the Homely M890G Digital Multimeter package, including the multimeter, red and black test leads, a K-type thermocouple, and the instruction manual.
4. Pwodwi souview
The Homely M890G Digital Multimeter features a robust design with a clear LCD display and a rotary switch for function selection.
4.1 Aranjman Panèl Devan an

Figi 4.1: Devan detaye view of the M890G multimeter, highlighting the LCD display, function rotary switch, and input terminals. The display shows '00.0' and test leads are connected.
- Ekspozisyon LCD: Montre lekti mezi, inite, ak endikatè fonksyon.
- Rotary switch: Used to select the desired measurement function (e.g., V~, V=, A~, A=, Ω, °C, Hz, F, Diode, hFE).
- Bouton Fonksyon: (e.g., HOLD, RANGE, REL, Hz/DUTY, SELECT) for additional features.
- Jack Antre:
- COM: Common terminal for the black test lead.
- VΩHz: Antre pou voltage, resistance, frequency, capacitance, diode, and continuity measurements (red test lead).
- mA: Antre pou miliampmezi kouran (plon tès wouj).
- 20A MAX: Antre pou mezi kouran ki wo jiska 20A (plon tès wouj).
4.2 Rear Features

Figi 4.2: Views of the M890G multimeter from the side and rear, illustrating the integrated kickstand for hands-free operation and the battery compartment cover.
- Kickstand: Allows the meter to stand upright for easier viewing.
- Lòj batri: Located on the rear, secured by screws, for battery replacement.
5. Enstalasyon
5.1 Enstalasyon batri
The M890G multimeter requires a 9V battery (not always included). To install or replace the battery:
- Asire w ke miltimèt la etenn epi fil tès yo dekonekte.
- Jwenn kouvèti konpatiman pil la sou dèyè mèt la.
- Unscrew the retaining screw(s) and carefully remove the cover.
- Konekte yon nouvo pil 9V nan klip pil la, pandan w ap obsève polarite ki kòrèk la.
- Mete pil la nan konpatiman an epi remete kouvèti a, byen sere l ak vis(yo).
5.2 Konekte fil tès yo
Toujou konekte fil tès nwa a nan COM jack. Connect the red test lead to the appropriate input jack based on the measurement type:
- Pou Voltage, Resistance, Capacitance, Frequency, Diode, and Continuity measurements, connect the red lead to the VΩHz Jack.
- For current measurements up to 500mA, connect the red lead to the mA Jack.
- Pou mezi kouran jiska 20A, konekte fil wouj la ak 20A MAX Jack.
6. Operasyon Enstriksyon
Before taking any measurement, ensure the test leads are correctly connected and the rotary switch is set to the desired function and range.
6.1 Power On/Off
Turn the rotary switch from the OFF position to any desired function to power on the meter. To power off, turn the rotary switch back to the OFF position. The meter features an auto power-off function to conserve battery life after a period of inactivity.
6.2 Mezire DC Voltage (V=)
- Konekte plon tès nwa a COM ak fil tès wouj la pou VΩHz.
- Mete switch rotary la sou volim DC ou vle a.tage (V=) range. If the voltage se enkoni, kòmanse ak entèval ki pi wo a epi diminye jan sa nesesè.
- Konekte fil tès yo an paralèl ak sikwi a oswa konpozan ki anba tès la.
- Li voltage valè sou ekspozisyon LCD a.
6.3 Mezire AC Voltage (V~)
- Konekte plon tès nwa a COM ak fil tès wouj la pou VΩHz.
- Mete switch rotary la sou volim AC ou vle a.tage (V~) ranje.
- Connect the test leads in parallel to the AC source or component.
- Li voltage valè sou ekspozisyon LCD a.
6.4 Mezire Rezistans (Ω)
- Asire w sikwi a pa gen enèji anvan ou mezire rezistans lan.
- Konekte plon tès nwa a COM ak fil tès wouj la pou VΩHz.
- Set the rotary switch to the desired Resistance (Ω) range.
- Connect the test leads across the component whose resistance is to be measured.
- Li valè rezistans lan sou ekran LCD a.
6.5 Measuring DC Current (A=)
CAUTION: Never connect the meter in parallel to a voltage source when measuring current. This can blow the fuse or damage the meter.
- De-energize kous la.
- Konekte plon tès nwa a COMKonekte fil tès wouj la nan mA for currents up to 500mA, or to 20A MAX for currents up to 20A.
- Set the rotary switch to the appropriate DC Current (A=) range.
- Open the circuit where the current is to be measured and connect the meter in series with the load.
- Re-energize the circuit and read the current value on the LCD display.
6.6 Measuring Temperature (°C)
- Connect the K-type thermocouple to the appropriate input jacks (usually VΩHz epi COM, observing polarity if indicated).
- Set the rotary switch to the Temperature (°C) function.
- Mete pwent tèmokoupl la sou oswa toupre objè ki gen tanperati a pou mezire.
- Li valè tanperati a sou ekran LCD a.
6.7 Lòt Fonksyon
- Tès kontinwite: Set the rotary switch to the continuity symbol. A built-in buzzer will sound if the resistance is below a certain threshold.
- Tès dyòd: Set the rotary switch to the diode symbol. Connect the red lead to the anode and black lead to the cathode of the diode. The forward voltage gout ap parèt.
- Transistor hFE Test: Insert the transistor into the hFE socket on the meter, ensuring correct Emitter, Base, Collector (EBC) orientation for NPN or PNP types. Set the rotary switch to hFE.
- Kapasite (F): Set the rotary switch to the capacitance range. Connect the leads across the capacitor (ensure it is discharged first).
- Frekans (Hz): Set the rotary switch to the frequency range. Connect the leads to the signal source.
7. Antretyen
7.1 Netwayaj
Siye kontè a ak piblisiteamp twal ak yon savon dou. Pa sèvi ak pwodui abrazif oswa solvang. Kenbe tèminal antre yo pwòp kont pousyè tè ak imidite.
7.2 Ranplasman batri
When the low battery indicator appears on the display, replace the 9V battery as described in Section 5.1. Failure to do so may result in inaccurate readings.
7.3 Ranplasman Fuse
If the meter fails to measure current, the fuse may be blown. Refer to the specifications for the correct fuse type. To replace the fuse:
- Ensure the meter is off and all test leads are disconnected.
- Open the battery compartment cover (and potentially an additional fuse cover, depending on the model).
- Carefully remove the old fuse and replace it with a new one of the identical type and rating.
- Securely close all covers.
NAN. Depanaj
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Pa gen ekspozisyon oswa ekspozisyon fèb | Batri ki mouri oswa ki ba | Ranplase batri a 9V. |
| Lekti ki pa kòrèk | Incorrect function/range selected; poor test lead connection; low battery | Verify function/range; check lead connections; replace battery. |
| Pa ka mezire kouran an | Blown fuse; incorrect input jack | Check and replace fuse if necessary; ensure red lead is in mA or 20A MAX jack. |
| "OL" or "1" displayed | Overload (measurement exceeds range); open circuit | Select a higher range; check for open circuit in the component or leads. |
9. Espesifikasyon
| Karakteristik | Detay |
|---|---|
| Mak | Lakay |
| Nimewo Modèl | M890G |
| Kalite ekspozisyon | Digital Display |
| Sous pouvwa | Batri Powered (9V) |
| Tanperati Fonksyònman | 0 - 40 ℃ (32 - 104 ℉) |
| Dimansyon | Apeprè 176 x 88 x 38 mm |
| Kalite Mezi | Multimeter (AC/DC Volt, Amp, Ohm, Temperature, Frequency, Capacitance, Diode, hFE) |
| Konpozan ki enkli | Multimeter, Test Leads, K-Type Thermocouple |
10. Garanti ak sipò
For warranty information or technical support regarding your Homely M890G Digital Multimeter, please refer to the documentation provided at the time of purchase or contact your retailer. Keep your purchase receipt as proof of purchase.