SMART SENSOR AS8906

SMART SENSOR AS8906 Handheld NO2 Gas Leak Detector User Manual

Modèl: AS8906

1. Entwodiksyon

This manual provides instructions for the safe and effective operation of the SMART SENSOR AS8906 Handheld NO2 Gas Leak Detector. This device is designed for detecting Nitrogen Dioxide (NO2) gas concentrations in various environments. Please read this manual thoroughly before using the product.

1.1 Enfòmasyon sou Sekirite

  • Always operate the device in accordance with the instructions provided.
  • Do not attempt to modify or repair the device yourself. Refer to qualified personnel for service.
  • Ensure the device is charged using the provided charging adapter and USB cable.
  • Avoid exposing the device to extreme temperatures or humidity outside the specified operating conditions.
  • This device is intended for professional use and should be handled with care.

2. Pwodwi souview

2.1 Kontni pake a

Pake estanda a gen ladan atik sa yo:

  • 1 x Nitrogen Dioxide Gas Monitor (AS8906)
  • 1 x manyèl itilizatè
  • 1 x Chargement adaptè
  • 1 x USB kab
  • 1 x Hand Carry Case
  • 1 x Sètifika Kalibrasyon
  • 1 x CNEX Certificate
  • 1 x Gift Paper Box
Standard package contents of the SMART SENSOR AS8906 gas detector, including the device, carry case, charger, and documentation.

Figi 2.1: Kontni estanda nan pake a.

2.2 Konpozan Aparèy

Familiarize yourself with the main components of the AS8906 detector:

Devan view of the SMART SENSOR AS8906 NO2 gas detector with labeled components: High sensitive sensor, sampling pump connecting port, LCD screen, Down button, Up button, Sound alarm, Charging port, Light alarm, Power on/off button, Enter button.

Figi 2.2: Devan view and labeled components of the AS8906 detector.

  • High Sensitive Sensor: Detects NO2 gas concentration.
  • Sampling Pump Connecting Port: For attaching the optional sampling ponp.
  • Ekran LCD: Displays gas concentration, battery status, and other information.
  • Desann bouton: Used for navigation and decreasinvalè g yo.
  • Up bouton: Used for navigation and increasinvalè g yo.
  • Son alam: Emits an audible alert when gas concentration exceeds set limits.
  • Pò chaje: Pou konekte kab chaje USB a.
  • Limyè Alam: Visual alert (LED) when gas concentration exceeds set limits.
  • Pouvwa sou / Off bouton: Kontwole pouvwa aparèy la.
  • Bouton Antre: Konfime seleksyon ak paramèt.

2.3 Dimansyon

The AS8906 detector features a compact design for portability.

Kòt-a-kòt view of the SMART SENSOR AS8906 NO2 gas detector showing its dimensions: 120mm height, 64.5mm width, and 38.3mm depth.

Figi 2.3: Dimansyon aparèy la.

Dimansyon: 120.2mm (Wotè) x 64.5mm (Lajè) x 38.3mm (Pwofondè).

A person's hand placing the compact SMART SENSOR AS8906 NO2 gas detector into a jeans pocket, illustrating its portability.

Figure 2.4: The compact size allows for easy portability.

3. Enstalasyon

3.1 Chaje Aparèy la

The AS8906 detector is powered by a built-in 3.7V Li-battery. Before first use, ensure the device is fully charged.

  1. Locate the charging port at the bottom of the device.
  2. Konekte kab USB bay la nan pò chaje a.
  3. Connect the other end of the USB cable to the charging adapter.
  4. Plug the charging adapter into a standard power outlet.
  5. The battery indicator on the LCD screen will show charging status. A full charge typically provides up to 12 hours of continuous operation.
Fèmen view of the bottom of the SMART SENSOR AS8906 NO2 gas detector, highlighting the battery charging port.

Figure 3.1: Charging port location.

The SMART SENSOR AS8906 NO2 gas detector connected to its charging adapter and USB cable.

Figure 3.2: Gas detector with recharge adapter.

3.2 Konekte Sampling Pump (Optional)

The optional sampling pump (AS8930) is designed to assist the gas detector in environments with limited access or poor air circulation. It does not operate independently and requires power from the gas detector.

  1. Aliman s laampling pump with the gas detector's sampling pump connecting port.
  2. Securely attach the sampling pump to the gas detector using the two closed-type screws. Ensure a tight connection to avoid poor contact.
  3. Connect the soft rubber tube (500mm long) to the nozzle of the sampling ponp.
  4. Enpòtan: Do not connect any other voltage power supply to the sampling pump to prevent damage.
Eleman nan sampling pump accessory, including the pump unit, user manual, warranty card, soft rubber tube, and color paper box.

Figi 3.3: Sampling pump and accessories.

4. Operasyon

4.1 Limen/Etenyen

  • Pou limen: Peze epi kenbe la Bouton On/Off until the LCD screen illuminates. The device will perform a self-test.
  • Pou etenn: Peze epi kenbe la Bouton On/Off jiskaske ekran an etenn.

4.2 Konprann ekspozisyon an

The high-density digital LCD screen displays real-time gas concentration values, battery status, and other operational indicators. The backlight function allows for use in dark areas.

  • PPM: Indicates parts per million, the unit for gas concentration.
  • Ikon batri: Montre nivo chaj batri aktyèl la.
  • Endikatè alam: Visual cues for alarm status.

4.3 Fonksyon alam

The device features high and low alarm functions with three alert methods: sound, light, and vibration. Alarm values are adjustable.

  • When the gas concentration reaches a preset high or low alarm value, the device will activate its sound, light, and vibration alarms.
  • The alarm sound can reach up to 80dB.

4.4 Adjusting Alarm Values

Refer to the on-screen menu for adjusting high and low alarm thresholds. Use the Up epi Desann buttons to navigate and change values, and the Antre bouton pou konfime.

4.5 Using the Sampling Ponp

Lè s laampling pump is connected, it will draw air into the detector, allowing for gas concentration measurement in remote or confined spaces. The air flow velocity is approximately 0.5 cubic inches per hour, with a maximum gas sample collecting distance of about 50 feet.

5. Antretyen

5.1 Swen Batri

  • Recharge the device when the battery indicator shows low power to ensure continuous operation.
  • Evite vide batri a nèt souvan pou pwolonje dire lavi li.
  • If storing the device for an extended period, charge it to approximately 50% and recharge every few months.

5.2 Netwayaj

  • Siye eksteryè aparèy la ak yon mou, damp twal.
  • Pa sèvi ak pwodui netwayaj abrazif oswa solvan, paske sa yo ka domaje c la.asing oswa ekran.
  • Ensure no liquids enter the sensor area or charging port.

5.3 Kalibrasyon

The device comes with a calibration certificate. For optimal accuracy and compliance, periodic professional calibration is recommended. Refer to the manufacturer or authorized service centers for calibration services.

NAN. Depanaj

If you encounter issues with your AS8906 detector, refer to the following common problems and solutions:

PwoblèmKòz posibSolisyon
Aparèy pa limen.Batri ki fèb oswa ki vid.Charge the device using the provided adapter and USB cable.
Lekti ki pa kòrèk.Sensor contamination or need for calibration.Ensure the sensor area is clean. Consider professional calibration if readings remain inconsistent.
Alarm not sounding/lighting/vibrating.Alarm settings configured incorrectly or disabled.Check alarm settings in the device menu. Ensure volume and vibration are enabled.
Sampling pump not working.Poor connection to the detector or pump malfunction.Asire s laampling pump is securely attached with screws. Verify the detector is powered on.

If the problem persists after attempting these solutions, contact customer support for further assistance.

7. Espesifikasyon

7.1 Espesifikasyon detektè

KarakteristikDetay
MakSMART CAPTEUR
ModèlAS8906
Kalite gazdiyoksid nitwojèn (NO2)
Ranje Mezi0 ~ 20 ppm
Rezolisyon0.1 ppm
Prensip travayCapteur elektwochimik
Kalite AlamSound, Light, Vibration (adjustable values)
Nivo son alamJiska 80dB
Tanperati Fonksyònman-10 ~ 50 ° C
Operasyon Imidite15~95% RH (standard)
Sous pouvwa3.7V Li-battery (Built-in)
Travay aktyèl16mA
Operasyon kontinyèlApeprè 12 èdtan (chaj konplè)
MateryèlABS plastik
Pwa nèt200g (7.1 ons)
Dimansyon120.2 x 64.5 x 38.3 mm
SètifikasyonJJG693; JJG695: JJG915 and GB3836 series anti-explosion standard, CNEX

7.2 Sampling Pump Specifications (Optional Accessory)

KarakteristikDetay
Opere Voltage RangeDC 2.2V-3.2V
Travay aktyèl<280mA
Dyamèt bouch2.5mm
Bri<75 dB
Dimansyon100.8 x 62.3 x 50 mm
Max Sample DistanceApeprè. 50 pye
Air Flow VelocityApprox. 0.5 cubic inches per hour

8. Garanti ak sipò

8.1 Enfòmasyon sou Garanti

Your SMART SENSOR AS8906 Handheld NO2 Gas Leak Detector comes with a warranty. Please refer to the included Warranty Card in your package for specific terms and conditions, including warranty period and coverage details.

8.2 Sipò pou Kliyan

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact SMART SENSOR customer support. Contact information can typically be found on the product packaging, the warranty card, or the official SMART SENSOR websit.