This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Goodman GR9T960803BN 96% AFUE Two-Stage Natural Gas Furnace. This unit is designed for upflow or horizontal configurations and features an 80,000 BTU capacity with low NOx emissions. Please read this manual thoroughly before installation or operation.

Goodman GR9T960803BN Natural Gas Furnace front view

Figi 1: Devan view of the Goodman GR9T960803BN Natural Gas Furnace.

2. Enfòmasyon sou Sekirite

AVÈTISMAN: Enstalasyon, ajisteman, chanjman, sèvis oswa antretyen ki pa kòrèk ka lakòz domaj nan pwopriyete, blesi pèsonèl oswa pèt lavi. Enstalasyon ak sèvis dwe fèt pa yon enstalatè ki kalifye, ajans sèvis, oswa founisè gaz la.

  • Toujou dekonekte kouran anvan ou fè sèvis inite a.
  • Asire bon vantilasyon ak ekipman pou lè combustion.
  • Do not store flammable materials near the furnace.
  • Enstale detektè monoksid kabòn lakay ou.
  • Never operate the furnace if any part has been submerged in water.
  • This appliance uses natural gas. Ensure all gas connections are leak-free.

3. Enstalasyon ak Enstalasyon

Installation of this furnace must be performed by a qualified HVAC professional. The unit is designed for upflow or horizontal installation. Refer to local codes and the complete installation manual provided with the unit for detailed instructions.

3.1 Chèk Pre-Enstalasyon

  • Verify that the furnace model matches the required specifications for your home.
  • Ensure adequate space for installation and future servicing.
  • Confirm that the electrical supply (115V) and natural gas line are available and correctly sized.

3.2 Plasman Inite

The furnace can be installed in an upflow or horizontal position. Proper clearances from combustible materials must be maintained as per local codes and manufacturer guidelines. The unit dimensions are approximately 34.5"D x 17.5"W x 34.5"H.

Goodman GR9T960803BN Natural Gas Furnace with dimensions

Figure 2: Dimensions of the Goodman GR9T960803BN Natural Gas Furnace.

3.3 Koneksyon

  • Konduit: Connect supply and return air ducts securely.
  • Tiyo Gaz: Connect the natural gas supply line to the furnace gas valve. Ensure all connections are tested for leaks.
  • Elektrik: Wire the furnace to a dedicated 115V circuit as per wiring diagrams.
  • Vantilasyon: Install proper venting for combustion byproducts.
  • Drenaj kondansasyon: Connect the condensate drain line to an appropriate drainage system.
Entèn view of Goodman furnace showing burner, wiring, and control board

Figure 3: Internal components of the furnace, including the burner assembly and control board.

4. Operasyon Enstriksyon

Once installed by a qualified professional, your Goodman furnace operates automatically based on your thermostat settings.

4.1 Starting the Furnace

  1. Ensure the gas supply valve to the furnace is open.
  2. Limen pouvwa elektrik nan gwo founo dife a.
  3. Set your thermostat to the "Heat" mode and adjust the temperature setting above the current room temperature.
  4. The furnace will initiate its start-up sequence, which includes a pre-purge, ignition, and main burner operation.

4.2 De-Stage Operasyon

This furnace features two-stage heating. In mild weather, it will operate at a lower capacity (first stage) for longer periods, providing more consistent temperatures and greater efficiency. During colder periods, or if the thermostat calls for more heat, it will switch to full capacity (second stage) to quickly reach the desired temperature.

4.3 Shutting Down the Furnace

  1. Set your thermostat to the "Off" mode or lower the temperature setting below the current room temperature.
  2. For extended shutdowns (e.g., summer), turn off the electrical power to the furnace and close the manual gas shut-off valve.

5. Antretyen

Regular maintenance ensures the longevity and efficiency of your furnace. Some tasks can be performed by the homeowner, while others require a qualified HVAC technician.

5.1 Homeowner Maintenance

  • Ranplasman filtè lè: Check the air filter monthly and replace it every 1-3 months, or more frequently if you have pets or allergies. A dirty filter restricts airflow and reduces efficiency.
  • Clear Area Around Furnace: Ensure the area around the furnace is clear of obstructions, especially combustible materials, to allow for proper airflow and safe operation.
  • Drenaj kondansasyon: Periodically check the condensate drain line for blockages.

5.2 Antretyen Pwofesyonèl

It is recommended to have your furnace inspected and serviced annually by a qualified HVAC technician. This service typically includes:

  • Tcheke epi netwaye echanjeur chalè a.
  • Inspecting the burner assembly and igniter.
  • Verifying gas pressure and connections.
  • Tès kontwòl sekirite ak konpozan elektrik yo.
  • Lubrifyan pati k ap deplase yo (si sa aplikab).
  • Checking flue and ventilation systems.
Top view of Goodman furnace showing heat exchanger tubes

Figure 4: Top internal view showing the heat exchanger tubes. Regular inspection of these components is part of professional maintenance.

NAN. Depanaj

Anvan ou rele pou sèvis, review the following common issues and solutions. For complex problems, contact a qualified HVAC technician.

PwoblèmKòz posibSolisyon
Founo a pa chofeThermostat set incorrectly, power off, gas valve closed, dirty air filter, pilot light/igniter issue.Check thermostat settings, ensure power is on, open gas valve, replace air filter. If igniter issue, contact technician.
Operasyon fè bwiLoose panels, dirty blower wheel, motor issues.Ensure all access panels are secured. If noise persists, contact technician.
Blower kouri kontinyèlmanThermostat fan setting on "ON", faulty thermostat, control board issue.Set thermostat fan to "AUTO". If issue persists, contact technician.
Flux lè fèbDirty air filter, blocked return air vents, duct leaks.Replace air filter, clear vents. Inspect ductwork for leaks.

7. Espesifikasyon

Key specifications for the Goodman GR9T960803BN Natural Gas Furnace:

KarakteristikDetay
Nimewo ModèlGR9T960803BN
MakGoodman
AFUE Efikasite96%
StagesDe-Stage
Kapasite BTU80,000 BTU
Kalite gazGaz natirèl
Emisyon NOxBa NOx
KonfigirasyonUpflow / Orizontal
Kalite motèMulti-speed blower
Voltage115V
Dimansyon (D x W x H)34.5" x 17.5" x 34.5"
Echanjeur chalèHeavy-duty aluminized-steel tubular (primary), Stainless-steel (secondary)
IgniterDurable silicon nitride

8. Enfòmasyon sou Garanti

This Goodman furnace comes with a 10-ane pati garanti limite. To qualify for this warranty, the unit must be installed by a qualified installer and registered online within 60 days of installation. Failure to register the product within this timeframe may result in a shorter warranty period. Please retain your proof of purchase and installation records.

9. Sipò ak Sèvis

For technical assistance, service, or warranty claims, please contact a qualified HVAC professional or the Goodman customer support. Do not attempt to service the unit yourself beyond the basic homeowner maintenance described in this manual.

You can find more information and locate authorized service providers on the official Goodman websit: www.goodmanmfg.com

© 2024 Goodman Manufacturing. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.