Zoeller M267

Zoeller Model M267 Waste-Mate 260 Series Sewage Pump Instruction Manual

Model: M267 | Part Number: 267-0050

1. Entwodiksyon

This manual provides essential instructions for the safe installation, operation, and maintenance of your Zoeller Model M267 Waste-Mate 260 Series Sewage Pump. This submersible pump is designed for residential or light commercial dewatering and wastewater applications, capable of transferring groundwater, effluent, or raw sewage. Its vortex impeller design helps prevent clogging and allows for the passage of 2-inch spherical solids.

2. Enfòmasyon sou Sekirite

Read all instructions carefully before installation and operation. Failure to follow these instructions may result in serious injury, death, or property damage.

  • Always disconnect power to the pump before attempting any installation, service, or maintenance.
  • Ensure all electrical connections are made by a qualified electrician and comply with local codes and regulations.
  • Do not operate the pump in an explosive atmosphere or pump flammable liquids.
  • Mete ekipman pwoteksyon pèsonèl (PPE) ki apwopriye pandan enstalasyon ak sèvis.
  • Asire w ponp lan byen konekte a tè pou anpeche chòk elektrik.
  • Do not lift the pump by its power cord or float switch cord. Use the integrated handle.
  • This pump is designed for water and sewage only. Do not use for other liquids.

3. Enstalasyon ak Enstalasyon

3.1. Location and Sump Requirements

Install the pump in a sump pit that is adequately sized for the expected flow rate and pump dimensions. Ensure the pit is clean and free of debris before placing the pump.

3.2. Koneksyon plonbri

  • Connect the discharge piping to the pump's 2-inch NPT vertical discharge.
  • Use a check valve in the discharge line to prevent backflow into the sump.
  • Ensure all connections are watertight and sealed properly.

3.3. Koneksyon elektrik

  • The pump operates on 115 Volts, 1 Phase power.
  • Connect the 10-foot, UL listed 3-wire neoprene cord and plug to a dedicated, properly grounded electrical outlet.
  • Ensure the circuit is protected by a fuse or circuit breaker of appropriate rating.
  • The pump features an oil-filled, hermetically sealed motor with automatic reset thermal overload protection.

3.4. Float Switch Adjustment

The pump is equipped with a mechanical float switch for automatic operation. The float switch is pre-set with an "On" point at approximately 12 inches and an "Off" point at approximately 4 inches. Ensure the float switch can move freely without obstruction within the sump pit.

4. Operasyon

The Zoeller Model M267 pump is designed for automatic operation via its mechanical float switch. Once properly installed and connected to power, the pump will activate when the water level rises to the "On" point (approximately 12 inches) and will continue to pump until the water level drops to the "Off" point (approximately 4 inches).

  • Premye kòmansman: After installation, allow the sump to fill with water to the "On" level to verify proper pump operation and float switch function.
  • Siveyans kontinyèl: Periodically check the sump pit to ensure the pump is operating as expected and the float switch is not obstructed.

5. Antretyen

Regular maintenance ensures optimal performance and extends the life of your pump. Always disconnect power before performing any maintenance.

5.1. Routine Inspection (Monthly)

  • Sump Pit: Remove any debris, dirt, or foreign objects from the sump pit that could interfere with pump or float switch operation.
  • Flote switch: Manually lift and lower the float switch to ensure it moves freely and activates/deactivates the pump correctly.
  • Kòd pouvwa: Inspect the power cord for any signs of damage, fraying, or wear.

5.2. Annual Inspection

  • Impeller: If accessible, inspect the cast iron non-clogging vortex impeller for any buildup or damage. Clean as necessary.
  • Lojman ponp: Check the durable cast iron pump housing and powder-coated epoxy finish for any signs of corrosion or damage. The epoxy finish is designed to prevent corrosion and provide heat dissipation.
  • Seals: Inspect the carbon and ceramic shaft seal and neoprene square ring & gasket for leaks or wear. Replacement may require professional service.

NAN. Depanaj

Before attempting any troubleshooting, always disconnect power to the pump.

PwoblèmKòz posibSolisyon
Ponp pa mache.No power; tripped circuit breaker; faulty float switch; motor overload.Check power supply; reset breaker; inspect float switch for obstruction; allow motor to cool (thermal overload reset).
Ponp kouri men li pa ponpe dlo.Air lock; clogged impeller; discharge pipe obstruction; low water level.Ensure pump is fully submerged; clear impeller/discharge pipe; wait for water level to rise.
Ponp kouri kontinyèlman.Float switch stuck in "On" position; continuous inflow; faulty check valve.Inspect float switch for obstruction; check for continuous water source; inspect/replace check valve.
Ponp sik twò souvan.Sump pit too small; float switch differential too narrow; backflow from discharge.Consult a professional for sump sizing; adjust float switch (if adjustable, or replace); inspect check valve.

7. Espesifikasyon

KarakteristikDetay
ModèlM267
Nimewo Pati267-0050
Puissance (HP)1 / 2 HP
Voltage115 Volts
Faz1 Faz
Egzeyat Size2 inch NPT Vertical
Pousantaj maksimòm koule125 GPM (galon pou chak minit)
Maksimòm tèt22 pye
Longè kòd10 pye
Manyen solid2 inch spherical solids
Chanje KaliteMechanical Float Switch (Automatic)
On Point12 pous
Off Point4 pous
MateryèlJete fè, Nerjaveèi
Pwoteksyon motèAutomatic Reset Thermal Overload

8. Garanti ak sipò

8.1. Enfòmasyon sou Garanti

Zoeller Company warrants its products against defects in material and workmanship for a specified period from the date of purchase. For specific warranty terms and conditions applicable to your Model M267 pump, please refer to the warranty card included with your product or visit the official Zoeller websit la. Kenbe resi acha ou kòm prèv acha.

8.2. Sipò teknik

For technical assistance, troubleshooting beyond this manual, or to inquire about replacement parts, please contact Zoeller customer service. Have your pump model number (M267) and serial number ready when contacting support.

Anjeneral, ou ka jwenn enfòmasyon kontak sou fichye manifakti a. websit la oubyen sou anbalaj pwodwi a.

© 2023 Zoeller Company. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.