1. Entwodiksyon
Thank you for choosing the Vortice Spiral Extractor Fan. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new ventilation unit. Please read these instructions thoroughly before installation and retain them for future reference.
This fan is designed for bathroom air exchange, featuring a non-return valve to prevent backflow. It operates on 220/240V, 50Hz electrical supply.
2. Enstriksyon Sekirite
Pou asire yon operasyon an sekirite epi pou anpeche domaj, toujou respekte règ sekirite sa yo:
- Sekirite elektrik: Installation and electrical connections must be performed by a qualified electrician in accordance with local wiring regulations and standards. Disconnect power at the main circuit breaker before any installation, maintenance, or repair work.
- Itilizasyon entansyonèl: This appliance is designed for extracting air from domestic bathrooms and similar environments. Do not use it for purposes other than its intended use.
- Timoun ak moun ki vilnerab: Timoun ki gen laj 8 an ak pi wo a ak moun ki gen kapasite fizik, sansoryèl oswa mantal redwi oswa ki pa gen eksperyans ak konesans yo kapab itilize aparèy sa a si yo te ba yo sipèvizyon oswa enstriksyon konsènan itilizasyon aparèy la an sekirite epi yo konprann danje ki genyen ladan yo. . Timoun yo pa dwe jwe ak aparèy la. Netwayaj ak antretyen itilizatè pa dwe fèt pa timoun san sipèvizyon.
- Vantilasyon: Ensure adequate ventilation in the room where the fan is installed to prevent the backflow of gases from open-flued appliances.
- Antretyen: Regular cleaning and maintenance should only be performed after disconnecting the power supply.
- Domaj: Do not operate the fan if the power cord or casing is damaged. Contact qualified personnel for repairs.
3. Pake kontni
Verifye ke tout konpozan yo prezan epi yo pa domaje lè w ap debale yo:
- Vortice Spiral Extractor Fan Unit
- Vis ak ploge miray pou monte
- Manyèl Enstriksyon
Note: Additional tools for installation (e.g., drill, screwdriver, wire strippers) are not included.
4. Enstalasyon ak Enstalasyon
Before beginning installation, ensure the main power supply to the installation area is switched off.
4.1 Enstalasyon Vantilatè a
The Vortice Spiral Extractor Fan can be mounted on a wall or ceiling. Choose a location that allows for effective air extraction and is away from direct water spray.
- Prepare Ouvèti a: Create a circular opening in the wall or ceiling suitable for the fan's ducting. Ensure the opening is clean and free of debris.
- Pozisyon fanatik la: Place the fan unit against the mounting surface, ensuring it is level. Mark the positions for the mounting screws.
- Fè twou: Drill pilot holes at the marked positions. Insert wall plugs if necessary.
- Fikse vantilatè a: Attach the fan securely to the wall or ceiling using the provided screws. Ensure the fan is firmly fixed and does not wobble.

Image 1: Vortice Spiral Extractor Fan installed on a ceiling. This image shows the fan mounted flush with a white ceiling, providing an example nan yon enstalasyon tipik.

Image 2: Vortice Spiral Extractor Fan installed on a wall. This image illustrates the fan mounted on a light grey wall, with the ducting extending through a brick wall section.

Imaj 3: Seksyon kwa view of Vortice Spiral Extractor Fan installation through a wall. This diagram shows the internal ducting of the fan passing through a brick wall, highlighting the through-wall installation method.
4.2 Koneksyon elektrik
WARNING: Electrical connections must be carried out by a qualified electrician. Ensure power is disconnected before proceeding.
- Access Wiring Terminal: Carefully open the fan casing to access the electrical wiring terminal block.
- Konekte fil yo: Connect the live (L), neutral (N), and earth (E) wires from your electrical supply to the corresponding terminals on the fan. Refer to the wiring diagram inside the fan casing for specific connections.
- Koneksyon an sekirite: Asire w ke tout koneksyon fil yo sere epi an sekirite.
- Fèmen Casing: Carefully close the fan casing, ensuring no wires are pinched.

Imaj 4: Devan view of Vortice Spiral Extractor Fan. This image displays the complete fan unit from the front, showing its white grille and central motor housing.
5. Operasyon Enstriksyon
Once installed and electrically connected, the Vortice Spiral Extractor Fan is ready for operation.
- Pouvwa sou: Restore power to the fan at the main circuit breaker.
- Aktivasyon: The fan is typically activated via a separate light switch or a dedicated fan switch in the bathroom. Consult your electrician regarding the specific wiring configuration.
- Valv anti-retou: The integrated non-return valve automatically opens when the fan is operating and closes when it is off, preventing cold air or drafts from entering the room.
6. Antretyen
Regular maintenance ensures optimal performance and longevity of your extractor fan. Always disconnect power before performing any maintenance.
6.1 Netwaye fanatik la
- Dekonekte pouvwa: Switch off the electrical supply to the fan at the main circuit breaker.
- Retire griyaj: Carefully unclip or unscrew the front grille of the fan.
- Konpozan pwòp: Sèvi ak yon mou, damp cloth to wipe down the grille, fan blades, and internal surfaces. For stubborn dirt, a mild detergent can be used. Avoid abrasive cleaners or solvents.
- Seche byen: Ensure all components are completely dry before reassembling.
- Remonte: Reattach the front grille securely.
- Retabli pouvwa: Switch the electrical supply back on.
Frequency: Clean the fan every 3-6 months, or more frequently in dusty or high-humidity environments.
NAN. Depanaj
Refer to the table below for common issues and their potential solutions. If the problem persists, contact a qualified technician.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Fanatik pa limen | No power supply; Loose wiring; Faulty switch; Motor failure. | Check circuit breaker; Verify wiring connections (by a qualified electrician); Test switch; Contact service. |
| Fanatik fè bwi | Dirty fan blades; Loose mounting; Obstruction in ducting; Worn motor bearings. | Clean fan blades; Tighten mounting screws; Check ducting for blockages; Contact service. |
| Poor air extraction | Blocked grille or ducting; Fan running too slowly; Non-return valve stuck. | Clean grille and ducting; Ensure fan is operating at full speed; Check non-return valve for obstructions. |
8. Espesifikasyon
Technical details for the Vortice Spiral Extractor Fan, Model B07DML3PKX:
| Karakteristik | Detay |
|---|---|
| Modèl | B07DML3PKX |
| Mak | Toubiyon |
| Voltage | 220/240 vòlt |
| Frekans | 50 Hz |
| Koulè | Blan |
| Dimansyon (Pake) | 22.2 x 22 x 11 cm (8.74 x 8.66 x 4.33 pous) |
| Pwa (Pakè) | 1.21 kg (2.67 liv) |
| Karakteristik espesyal | Integrated Non-Return Valve |
9. Enfòmasyon sou Garanti
Vortice products are manufactured to high-quality standards. This product is covered by a manufacturer's warranty against defects in materials and workmanship from the date of purchase. The specific terms and duration of the warranty may vary by region. Please retain your proof of purchase for warranty claims.
The warranty does not cover damage resulting from improper installation, misuse, neglect, unauthorized repairs, or normal wear and tear. For detailed warranty terms, please refer to the documentation provided with your purchase or visit the official Vortice websit.
10. Sipò ak Kontak
If you require technical assistance, have questions about your Vortice Spiral Extractor Fan, or need to report a fault, please contact Vortice customer support.
- Manifakti: Toubiyon
- Websit: www.vortice.com (Please check for local country-specific websit)
- Sèvis Kliyan: Refer to the Vortice website or your purchase documentation for local contact information, including phone numbers and email addresses.
When contacting support, please have your product model (B07DML3PKX) and date of purchase readily available.