SellEton SL-700 Series Floor Scale with SL-7515-C Indicator

SellEton SL-700 Series Floor Scale and SL-7515-C Indicator User Manual

Model: SL-700 Series Floor Scale with SL-7515-C Indicator

1. Pwodwi souview

The SellEton SL-700 Series Floor Scale is a robust industrial weighing solution designed for heavy-duty applications. It features a durable carbon steel platform and is paired with the SL-7515-C metal indicator, offering accurate measurements and ease of use.

SellEton SL-700 Series Floor Scale with SL-7515-C Indicator

Image: SellEton SL-700 Series Floor Scale with SL-7515-C Indicator, showing the scale platform, indicator, connecting cable, and adjustable feet.

SellEton SL-700 Industrial Digital Floor Scale

Image: An industrial digital floor scale from the SL-700 series, pre-calibrated and ready for use.

SellEton SL-7515-C Indicator

Image: Close-up of the SellEton SL-7515-C indicator, featuring an LCD screen and control buttons.

Karakteristik kle:

  • Konstriksyon lou: Professional-grade carbon steel floor scale suitable for industrial and shipping use.
  • Segondè Presizyon: Capable of handling up to 2,500-pound loads with 0.5 lb accuracy.
  • Durable Load Cells: Four high-quality alloy load cells ensure accuracy across the full capacity range.
  • Endikatè itilizatè-zanmitay: Includes an easy-to-read LCD screen and intuitive controls.
  • Konsepsyon solid: Protected against dust, splash water, or immersion, ensuring durability in demanding environments.

Pwosesis Faktori:

Videyo: Finiview of the manufacturing process for SellEton floor scales, highlighting the use of advanced technology and precision craftsmanship in the USA.

2. Enfòmasyon sou Sekirite

Please read and understand all safety instructions before operating the scale. Failure to follow these instructions may result in injury or damage to the equipment.

  • Ensure the scale is placed on a stable, level surface to prevent tipping and ensure accurate readings.
  • Do not exceed the maximum weight capacity of 2,500 lbs (1134 kg). Overloading can damage the load cells and compromise accuracy.
  • Keep the scale and indicator away from excessive moisture, dust, and extreme temperatures unless specifically designed for such environments.
  • Avoid dropping heavy objects onto the scale platform, as this can cause damage.
  • Dekonekte kouran an anvan ou netwaye oswa fè nenpòt antretyen.
  • Only use approved power adapters and cables.

3. Enstalasyon

Follow these steps to set up your SellEton SL-700 Series Floor Scale and SL-7515-C Indicator.

3.1 Debalaj ak plasman

  1. Ak anpil atansyon retire tout eleman nan anbalaj la.
  2. Place the scale platform on a firm, level surface. Ensure there is adequate space around the scale for safe operation and loading.
  3. Adjust the four adjustable feet on the scale platform to ensure it is level and stable. Use a spirit level for best results.

3.2 Load Cell Installation (if not pre-installed)

If your load cells are not pre-installed, refer to the following video for a step-by-step guide:

Video: Detailed instructions on how to install load cells in SellEton Floor Scales.

3.3 Connecting the Indicator

  1. Locate the load cell cable extending from the scale platform.
  2. Connect the load cell cable to the "Load Cell" port on the back of the SL-7515-C indicator. Ensure the connection is secure.
  3. Connect the power adapter to the "DC Power" port on the indicator and then plug it into a suitable power outlet.
Back of SellEton SL-7515-C Indicator

Imaj: Dèyè view of the SL-7515-C indicator, showing the DC Power, RS232, and Load Cell connection ports.

4. Operasyon Enstriksyon

This section details the basic operation of your SellEton SL-7515-C Indicator.

4.1 Power On/Off

  • Peze a ON/OFF button to turn the indicator on or off.

4.2 Zeroing the Scale

Before weighing, ensure the scale is empty and stable. If the display does not show 0.00, press the ZERO bouton pou reset li.

4.3 Konvèsyon inite

Pou chanje ant inite peze yo (pa egzanp, liv (lb) ak kilogram (kg)), peze bouton an UNIT/PRINT bouton.

4.4 Pwosedi pou peze

  1. Turn on the indicator and wait for it to display 0.00.
  2. Carefully place the item to be weighed onto the center of the scale platform.
  3. Li pwa ki parèt sou ekran LCD a.
  4. To weigh another item, remove the current item and wait for the display to return to 0.00, or press ZERO si sa nesesè.
SellEton SL-7515-C Indicator displaying weight

Image: Close-up of the SL-7515-C indicator showing a weight reading of 10000.00 lb.

Pallet on SellEton Floor Scale

Image: A pallet wrapped in plastic film placed on a SellEton floor scale for weighing.

4.5 Adjusting Zero and Negative Range

To adjust the zero range and negative range settings on your SL-7515-C indicator, follow the instructions in this video:

Video: Guide on adjusting the zero range and negative range settings for the SL-7515-C indicator.

5. Antretyen

Regular maintenance ensures the longevity and accuracy of your scale.

  • Netwayaj: Wipe the scale platform and indicator with a damp cloth. Avoid using abrasive cleaners or excessive water, especially near electronic components.
  • Enspeksyon: Periodically check all cables for damage and ensure connections are secure. Inspect the load cells and adjustable feet for any signs of wear or damage.
  • Kalibrasyon: For optimal accuracy, professional calibration is recommended periodically, especially after relocation or significant temperature changes.

NAN. Depanaj

Seksyon sa a bay solisyon pou pwoblèm komen ou ka rankontre.

6.1 Lekti ki pa egzak

  • Asire w ke balans lan sou yon sifas ki plat e ki estab.
  • Check that no objects are touching the scale platform or interfering with its movement.
  • Verify that the load cells are correctly installed and undamaged.
  • Consider professional calibration if inaccuracies persist.

6.2 Pwoblèm ekspozisyon

  • Check power connections and ensure the adapter is functioning correctly.
  • If the display is blank or erratic, try restarting the indicator.

6.3 Reset faktori

If you experience persistent issues or need to revert all settings to default, you can perform a factory reset. Note: This will not revert to an old calibration. You will need to calibrate your scale for proper readings after a factory reset.

Video: Demonstration on how to perform a factory reset on the SellEton SL-7515-C Indicator.

7. Espesifikasyon

KarakteristikDetay
MakSELLETON.COM ACCURATE SCALES WITH BETTER PRICING
ModèlSL-700 Series Floor Scale with SL-7515-C Indicator
MateryèlKabòn Steel
Lekti Presizyon0.5 liv
Kapasite maksimòm2,500 liv
Dimansyon platfòm5' x 4' (60" x 48")
Modèl EndikatèSL-7515-C
Endikatè DisplayEkran LCD
SellEton SL-7515-C Indicator Dimensions

Image: Technical drawing showing the dimensions of the SL-7515-C indicator.

8. Garanti

Every SellEton scale is backed by a 5-year warranty. For warranty claims or detailed information, please contact SellEton customer support.

9. Sipò

For further assistance, technical support, or to explore other SellEton products, please visit the official SellEton store:

Visit the SellEton Store on Amazon

© 2023 SellEton. Tout dwa rezève.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.