KING KB2410-1-B2-ECO

KING KB ECO2S Garage Heater Instruction Manual

Model: KB2410-1-B2-ECO

1. Entwodiksyon

This manual provides essential information for the safe and efficient operation of your KING KB ECO2S Garage Heater. The KB ECO2S series offers advanced heating solutions with an integrated electronic thermostat and remote control, designed for energy-efficient 2-stage heating. It features an Eco mode, fan-only operation, and timer functions, making it suitable for primary or supplemental heating in garages, workshops, and similar large spaces.

Tanpri li manyèl sa a byen anvan enstalasyon ak itilizasyon, epi konsève li pou referans pita.

KING KB ECO2S Garage Heater with remote control and mounting bracket

Image 1: KING KB ECO2S Garage Heater, showing the main unit, remote control, and mounting bracket.

2. Enfòmasyon enpòtan sou sekirite

AVÈTISMAN: Risk dife, chòk elektrik, oswa blesi pou moun.

  • Li tout enstriksyon yo anvan ou sèvi ak aparèy chofaj sa a.
  • Aparèy chofaj sa a cho lè l ap itilize. Pou evite boule, pa kite po ki pa kouvri a touche sifas cho yo. Kenbe materyèl ki ka pran dife, tankou mèb, zòrye, dra, papye, rad, ak rido, omwen 3 pye (0.9 m) lwen devan aparèy chofaj la epi kenbe yo lwen kote yo ak dèyè.
  • Li nesesè anpil prekosyon lè yo itilize nenpòt aparèy chofaj pa oswa toupre timoun oswa envalid epi chak fwa yo kite aparèy chofaj la fonksyone epi poukont li.
  • Pa opere okenn aparèy chofaj ak yon kòd oswa ploge ki domaje oswa apre aparèy chofaj la fonksyone byen, li te tonbe oswa domaje nan nenpòt fason. Jete aparèy chofaj, oswa retounen nan sant sèvis otorize pou egzamen ak/oswa reparasyon.
  • Pa sèvi ak deyò.
  • Aparèy chofaj sa a pa fèt pou itilize nan twalèt, zòn lesiv, ak menm kote andedan kay la. Pa janm jwenn aparèy chofaj kote li ka tonbe nan yon basen oswa nan yon lòt veso dlo.
  • Pa pase kòd anba tapi. Pa kouvri kòd la ak tapi jete, kourè, oswa kouvri menm jan an. Fè aranjman pou kòd lwen zòn trafik la ak kote li pa pral tonbe sou li.
  • Pou dekonekte aparèy chofaj, fèmen kontwòl yo, epi retire ploge nan priz.
  • Pa mete oswa kite objè etranje antre nan nenpòt vantilasyon oswa ouvèti tiyo echapman paske sa ka lakòz yon chòk elektrik oswa dife, oswa domaje aparèy chofaj la.
  • Pou anpeche yon dife posib, pa bloke admisyon lè oswa echapman nan okenn fason. Pa itilize sou sifas mou, tankou yon kabann, kote ouvèti yo ka bloke.
  • Yon aparèy chofaj gen pati cho ak arcing oswa etensèl andedan. Pa sèvi ak li nan zòn kote gazolin, penti, oswa vapè ki ka pran dife oswa likid yo itilize oswa estoke.
  • Sèvi ak aparèy chofaj sa a sèlman jan sa dekri nan manyèl sa a. Nenpòt lòt itilizasyon manifakti a pa rekòmande ka lakòz dife, chòk elektrik, oswa blesi sou moun.
  • This heater must be hardwired by a qualified electrician. Do not attempt to install or service this unit yourself if you are not qualified.

3. Pake kontni

Verifye ke tout konpozan yo prezan epi yo pa domaje anvan ou kontinye ak enstalasyon an.

  • KING KB ECO2S Garage Heater Unit
  • Universal Wall/Ceiling Mounting Bracket
  • Kontwòl Remote
  • Manyèl Enstriksyon (dokiman sa a)
KING KB ECO2S Garage Heater components

Image 2: The heater unit, mounting bracket, and remote control as included in the package.

4. Enstalasyon

IMPORTANT: This heater requires hardwiring to a 240V electrical supply. Installation must be performed by a qualified, licensed electrician in accordance with all local and national electrical codes.

4.1 Enstalasyon Aparèy Chofaj la

The heater comes with a universal bracket for wall or ceiling mounting. Ensure the mounting surface is structurally sound and capable of supporting the heater's weight (approximately 37.5 lbs).

  1. Select a mounting location that allows for proper air circulation and is at least 3 feet (0.9 m) away from combustible materials.
  2. Securely attach the universal bracket to the chosen wall or ceiling studs/joists using appropriate hardware (not included).
  3. Mount the heater unit onto the bracket. The bracket allows for adjustable positioning to direct heat flow.

4.2 Koneksyon elektrik

WARNING: Ensure power is disconnected at the main circuit breaker before attempting any electrical wiring.

  1. A dedicated 240V circuit with appropriate ampepòk (45 Amps for the 10000W model) is required.
  2. Access the internal wiring compartment of the heater. This typically involves removing a panel on the unit.
  3. Connect the supply wires to the heater's terminals as indicated in the wiring diagram located inside the heater's wiring compartment and in the full installation guide. Ensure proper grounding.
  4. Securely close the wiring compartment.
  5. Yon fwa enstalasyon an fini, retabli kouran an nan disjonktè a.
Dèyè view of KING KB ECO2S Garage Heater showing fan and wiring access

Imaj 3: Dèyè view of the heater, illustrating the fan and the typical location for electrical wiring access.

5. Operasyon Enstriksyon

The KB ECO2S heater can be operated using the integrated control panel or the included remote control.

5.1 Kontwòl Panel Overview

The front panel features a digital display and control buttons for power, mode selection, and temperature adjustment.

Close-up of KING KB ECO2S Garage Heater control panel

Imaj 4: Detaye view of the heater's control panel with digital display and buttons.

5.2 Fonksyon kontwòl Remote

The remote control provides convenient access to all heater functions from a distance.

  • Limen/Etenyen: Peze bouton pouvwa a pou limen oswa etenn aparèy chofaj la.
  • Ajisteman Tanperati: Use the up/down arrows to set the desired temperature. The digital display will show the set temperature.
  • Seleksyon mòd: Cycle through available modes (Heat, Eco, Fan Only, Timer) using the mode button.
  • Mòd ekolojik: Automatically adjusts wattage to maintain the set temperature efficiently.
  • Fan sèlman mòd: Operates the fan without engaging the heating elements, useful for air circulation.
  • Fonksyon revèy: Set a timer for automatic shut-off. Refer to the full manual for detailed timer programming.

5.3 Premye Operasyon

Upon first use, the heater may emit a slight odor as manufacturing oils burn off. This is normal and will dissipate quickly.

Set the desired temperature. The heater will operate in 2-stage heating, using the lowest wattage necessary to reach and maintain the set temperature, optimizing energy consumption.

Entèn view of KING KB ECO2S Garage Heater heating elements

Imaj 5: View of the spiral steel heating elements and fan, designed for efficient heat distribution.

6. Antretyen

WARNING: Disconnect power at the main circuit breaker before performing any maintenance.

  • Netwayaj: Netwaye deyò aparèy chofaj la detanzantan avèk yon twal mou, damp twal. Pa sèvi ak pwodui netwayaj abrazif oswa solvang.
  • Antre/Echapman lè: Ensure that the air intake and exhaust grilles are free from dust, debris, and obstructions. Use a vacuum cleaner with a brush attachment to gently clean these areas.
  • Enspeksyon Entèn: For internal cleaning or inspection, it is recommended to contact a qualified service technician.
  • Depo: If storing the heater for an extended period, ensure it is clean and dry. Store in a cool, dry place.

NAN. Depanaj

Anvan ou kontakte sèvis kliyan, re-view pwoblèm komen ak solisyon sa yo:

PwoblèmKòz posibSolisyon
Chofaj pa limen.No power supply; circuit breaker tripped; wiring issue.Check circuit breaker. Ensure proper electrical connection (consult electrician if unsure).
Aparèy chofaj la pa pwodui ase chalè.Incorrect temperature setting; room size exceeds heating capacity; poor insulation.Increase set temperature. Verify heater wattage is appropriate for the space (refer to specifications). Improve room insulation.
Heater cycles on/off frequently (clicking sound).Thermostat sensitivity; rapid temperature changes.This can be normal operation as the thermostat maintains temperature. If excessive, ensure proper air circulation around the unit and that the thermostat is not exposed to drafts. If the issue persists, contact customer support.
Remote kontwòl pa travay.Dead batteries; obstruction; out of range.Replace remote control batteries. Ensure no obstructions between remote and heater. Operate within recommended range.

8. Espesifikasyon

KarakteristikDetay
ModèlKB2410-1-B2-ECO
MakKING
Voltage240 Volts
Ampepòk45 Amps
Wattage10000 Watts
Kouvèti chofajUp to 900 sq ft (based on 8-ft ceiling height and FHA standard insulation values)
Dimansyon pwodwi (D x W x H)13.5" x 15" x 16.5"
Pwa atik37.5 liv
Karakteristik espesyalRemote Control, Electronic Thermostat, 2-Stage Heating, Eco Mode, Fan Only Mode, Timer
Kantite vitès2
Kalite gazElektrik
Kalite aliyeUniversal Wall/Ceiling Bracket (included)
Heating coverage chart for KING KB ECO2S Garage Heaters

Image 6: Heating coverage chart for various wattage models, including the 10000W model covering up to 900 sq ft.

9. Garanti ak sipò

For warranty information, technical support, or service inquiries, please refer to the official KING Electric websit la oubyen kontakte sèvis kliyan yo dirèkteman. Kenbe resi acha w la kòm prèv acha pou reklamasyon garanti.

Manufacturer: King Electric

Websit: www.king-electric.com

10. Videyo pwodwi yo

KING Electric - Smart Heating Solutions

Videyo 1: Yon overview of KING Electric's commitment to smart heating solutions and manufacturing quality.

© 2023 KING Electric. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.