DRUMMOND 63407
Manyèl Itilizatè Ponp ak Tank DRUMMOND 1 HP an Asye Nerjaveyab pou Pi Pa Fon
Model: 63407 | Brand: DRUMMOND
Pwodwi souview
This DRUMMOND 1 HP Stainless Steel Shallow Well Pump and Tank system is designed for residential water setups. It features a 5-gallon hardened steel alloy tank and a stainless steel housing and volute, ensuring durability and compatibility with potable water due to its lead-free fittings and rubber seals. The pump offers a maximum flow of 950 GPH and a total head lift of 115.5 ft., with a maximum well depth of 26 ft. It operates at 120 Volts (AC) and includes thermal protection with automatic reset for enhanced safety and longevity. The maximum water pressure is 50 PSI.

Image: The DRUMMOND 1 HP Stainless Steel Shallow Well Pump and Tank, featuring a green tank base, a stainless steel pump head, and a green motor housing. A pressure gauge and electrical control box are visible on the pump head.
Enfòmasyon enpòtan sou sekirite
Read and understand all safety warnings and instructions before operating this product. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.
- Always disconnect power before servicing or performing maintenance on the pump.
- Asire bon baz pou anpeche chòk elektrik.
- Do not operate the pump with damaged cords or plugs.
- Keep children and unauthorized persons away from the pump during operation.
- Install the pump in a dry, well-ventilated area, protected from freezing temperatures.
- Use only for pumping potable water as specified. Do not use for flammable liquids or corrosive chemicals.
- Ensure all plumbing connections are secure and leak-free before operation.
Enstriksyon Enstalasyon
- Debake: Retire tout konpozan yo nan anbalaj la avèk prekosyon. Enspekte pou wè si gen nenpòt domaj pandan transpò a.
- Kote: Choose a location that is dry, level, and protected from freezing. Ensure adequate ventilation around the pump.
- Montaj: Secure the pump to a stable surface using appropriate fasteners through the mounting holes on the base.
- Koneksyon plonbri:
- Connect the suction line from the well to the pump's inlet. Ensure the suction line is airtight to prevent air leaks.
- Connect the discharge line from the pump's outlet to your household plumbing system.
- Use thread sealant on all threaded connections to prevent leaks.
- Priming ponp lan:
- Remove the priming plug on the pump housing.
- Fill the pump housing completely with water until it overflows.
- Ranplase bouchon amorsaj la byen fèm.
- Koneksyon elektrik: Connect the pump to a dedicated 120V AC grounded electrical outlet. Ensure the circuit is protected by a ground fault circuit interrupter (GFCI). Consult a qualified electrician if unsure.
Enstriksyon Operasyon
- Premye kòmansman: After completing the setup and priming, turn on the power to the pump. The pump should start and begin to build pressure.
- Siveyans presyon: Observe the pressure gauge. The pump is designed to operate within a pressure range, typically turning on at a lower pressure (e.g., 30 PSI) and off at a higher pressure (e.g., 50 PSI).
- Lè nan sistèm nan: If the pump runs continuously or cycles frequently, there may be air in the system. Re-prime the pump and check all connections for air leaks.
- Operasyon nòmal: The pump will automatically turn on when water is drawn from the system and the pressure drops, and turn off when the pressure reaches its set maximum.
- Fèmen: To temporarily shut down the pump, turn off the electrical power. For extended periods of non-use, drain the pump and plumbing lines to prevent freezing.
Antretyen
Antretyen regilye asire lonjevite ak fonksyònman efikas ponp ou a.
- Enspeksyon anyèl: Annually inspect all plumbing connections for leaks and tighten as necessary. Check electrical connections for corrosion or damage.
- Verifikasyon Tank Presyon: Periodically check the air pre-charge in the pressure tank. This should be done when the tank is empty of water and the pump is off. Refer to the pressure tank's specific instructions for the correct pressure.
- Winterization: In areas subject to freezing temperatures, the pump and all exposed plumbing lines must be drained completely to prevent damage from ice expansion.
- Netwayaj: Keep the pump and motor free of dirt and debris to ensure proper cooling.
Depanaj
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Ponp pa kòmanse oswa kouri. | No power; tripped circuit breaker; faulty wiring; motor overload. | Check power supply; reset breaker; inspect wiring; allow motor to cool and reset thermal protection. |
| Pump runs but no water or low pressure. | Pump not primed; air leak in suction line; low water level in well; clogged impeller. | Re-prime pump; check all suction connections for leaks; verify well water level; inspect and clear impeller. |
| Ponp lan limen epi li etenn souvan. | Waterlogged pressure tank; air leak in system; faulty pressure switch. | Check and adjust pressure tank air charge; inspect for leaks; test or replace pressure switch. |
| Ponp fè bwi. | Air in pump; cavitation; worn bearings. | Re-prime pump; ensure adequate water supply; contact qualified service technician for bearing issues. |
Espesifikasyon teknik
| Karakteristik | Spesifikasyon |
|---|---|
| Mak | DRUMMOND |
| Nimewo Modèl | 63407 |
| Puissance | 1 HP |
| Pousantaj maksimòm koule | 950 GPH (15.83 galon pa minit) |
| Egzeyat | 1 pous |
| Total Lift tèt | 115.5 pye. |
| Maximum Well Depth | 26 pye. |
| Presyon dlo maksimòm | 50 psi |
| Kapasite tank | 5 gal. (hardened steel alloy) |
| Voltage | 120 Vòlt (AC) |
| Materyèl | Stainless Steel (housing and volute), Rubber |
| Pwa atik | 32.5 liv |
| Dimansyon (Pake) | 21 x 18 x 11 pous |
| Pwoteksyon tèmik | Otomatik Reyajiste |
Garanti ak sipò
This DRUMMOND product is backed by a manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions, including coverage duration and limitations. Keep your proof of purchase for warranty claims.
For technical assistance, troubleshooting beyond this manual, or warranty service, please contact DRUMMOND customer support. Contact information can typically be found on the product packaging or the manufacturer's official websit.
Note: Protection plans may be available for extended coverage. Check with your retailer for details.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.