BEST LEDR-1

BEST LEDR-1 LED Emergency Light User Manual

Model: LEDR-1

1. Entwodiksyon

This manual provides essential instructions for the safe installation, operation, and maintenance of your BEST LEDR-1 LED Emergency Light. Please read this manual thoroughly before installation and retain it for future reference. The LEDR-1 is designed to provide reliable emergency illumination during power outages, ensuring safety in commercial and residential environments.

2. Enstriksyon Sekirite Enpòtan

AVÈTISMAN: Risk pou chòk elektrik. Dekonekte kouran an anvan enstalasyon oswa antretyen.

  • Tout sèvis yo ta dwe fèt pa pèsonèl kalifye sèlman.
  • Pa monte tou pre aparèy chofaj gaz oswa elektrik.
  • Ensure the electrical wiring is properly grounded.
  • Pa sèvi ak li deyò. Aparèy sa a fèt pou itilizasyon andedan kay la sèlman.
  • Pa kite fil elektrik yo manyen sifas cho.
  • Mount the unit in locations and at heights where it will not be subjected to tamppa pèsonèl ki pa otorize.
  • Itilizasyon ekipman akseswar manifakti a pa rekòmande ka lakòz yon kondisyon danjere.
  • Pa sèvi ak ekipman sa a pou lòt itilizasyon li yo.
  • Allow battery to charge for a minimum of 24 hours after installation before testing.

3. Pake kontni

Verifye ke tout konpozan yo prezan epi yo pa domaje lè w ap ouvri pake a:

  • BEST LEDR-1 LED Emergency Light Fixture (1 unit)
  • Materyèl pou monte (vis, lank)
  • Fil nwa
  • Manyèl Itilizatè (dokiman sa a)
  • AA NiCAD Battery (pre-installed or included separately)

4. Pwodwi souview

The BEST LEDR-1 is a compact and efficient LED emergency light designed for wall-mount applications. It features a durable white thermoplastic housing and two adjustable LED lamp heads, providing 98 lumens of bright, white light (5000 Kelvin) during emergency situations. The unit operates on 120 Volts AC and includes a rechargeable NiCAD battery for backup power.

BEST LEDR-1 Emergency Light, front view

Figi 1: Devan view of the BEST LEDR-1 Emergency Light. This image shows the compact white thermoplastic housing with two adjustable LED lamp tèt.

Karakteristik kle:

  • Lojman: White Thermoplastic
  • Sous limyè: 2 LED heads
  • Voltage: X N ACT Volts AC
  • Batri: NiCAD, 90 minutes average life
  • Sòti limyè: 98 Lumen
  • Dimansyon: Approximately 14.75" L x 3.75" W x 3.75" H

5. Enstalasyon

The LEDR-1 is designed for flush wall mounting. Follow these steps for proper installation:

  1. Dekoneksyon pouvwa: Before beginning any installation, ensure that the main power supply to the circuit where the emergency light will be installed is turned OFF at the circuit breaker or fuse box.
  2. Kote montaj: Select a suitable wall location for mounting. The unit should be mounted at a height and in a position that allows for optimal light distribution during an emergency. Ensure the mounting surface is solid and can support the fixture's weight.
  3. Prepare Sifas Montage: Use the provided mounting hardware (screws and anchors) to secure the mounting plate or backplate of the emergency light to the wall. If the unit has a separate mounting plate, attach it first.
  4. Koneksyon fil elektrik:
    • Konekte a fil nwa from the emergency light to the fil cho (vivan) from the building's electrical supply.
    • Konekte a fil blan from the emergency light to the fil net from the building's electrical supply.
    • Konekte a fil vèt from the emergency light to the fil tè from the building's electrical supply.
    • Use the provided wire nuts to secure all connections. Ensure all connections are tight and properly insulated.
  5. Koneksyon batri: If the battery is not pre-connected, connect the battery pack to the circuit board. Ensure correct polarity.
  6. Aparèy sekirite: Carefully tuck all wires into the junction box or fixture housing. Secure the emergency light fixture to the mounting plate or wall according to the specific design of the unit.
  7. Retabli pouvwa: Once the installation is complete and all connections are secure, restore power to the circuit. The CHARGE INDICATOR light on the unit should illuminate, indicating that the battery is charging.
  8. Inisyal chaj: Allow the battery to charge for a minimum of 24 hours before performing the first test.

6. Operasyon

The BEST LEDR-1 Emergency Light operates automatically:

  • AC pouvwa sou: When AC power is supplied to the unit, the charge indicator light will be ON, and the battery will be charging. The LED lamp heads will remain OFF.
  • Pouvwa Outage: In the event of an AC power failure, the emergency light will automatically switch to battery backup mode, and the LED lamp heads will illuminate. The unit will provide emergency lighting for approximately 90 minutes.
  • AC Power Restored: When AC power is restored, the LED lamp heads will turn OFF, and the unit will revert to charging the battery.
  • Bouton tès: A test button is located on the unit. Pressing this button simulates an AC power failure, allowing you to verify that the emergency lights function correctly. Release the button to return to normal operation.
  • Reglabl Lamp Tèt: The two LED lamp heads can be manually adjusted to direct light to desired areas.

7. Antretyen

Regular maintenance ensures the longevity and reliability of your emergency light.

Tès batri:

Perform the following tests according to local codes and regulations (typically monthly and annually):

  • Tès chak mwa: Press and hold the test button for at least 30 seconds. The LED lamp heads should illuminate. Release the button; the lights should turn off, and the charge indicator should be ON.
  • Tès Anyèl: Disconnect AC power to the unit for a full 90 minutes. The LED lamp heads should remain illuminated for the entire duration. Reconnect AC power; the lights should turn off, and the charge indicator should be ON. If the unit fails to operate for the full 90 minutes, the battery may need replacement.

Netwayaj:

Clean the exterior of the unit and lamp heads periodically with a soft, damp twal. Pa sèvi ak pwodui netwayaj abrazif oswa solvang.

Ranplasman batri:

The NiCAD battery has a limited lifespan. If the unit fails the annual 90-minute test, the battery likely needs replacement. Contact a qualified electrician or the manufacturer for battery replacement instructions and compatible battery types.

NAN. Depanaj

PwoblèmKòz posibSolisyon
Emergency lights do not turn ON during power outage or when test button is pressed.
  • No AC power to the unit.
  • Battery not connected or faulty.
  • Batri a pa chaje nèt.
  • Faulty LED lamp tèt.
  • Tcheke koneksyon disjonktè a ak fil elektrik yo.
  • Ensure battery is properly connected. Allow 24 hours for initial charge.
  • Perform a 90-minute discharge test after 24-hour charge. Replace battery if necessary.
  • Kontakte pèsonèl sèvis kalifye.
Charge indicator light is OFF when AC power is present.
  • No AC power to the unit.
  • Faulty charge indicator LED.
  • Fòt sikwi entèn.
  • Tcheke koneksyon disjonktè a ak fil elektrik yo.
  • Kontakte pèsonèl sèvis kalifye.
Emergency lights do not stay ON for 90 minutes during annual test.
  • Batri a rive nan fen lavi li.
  • Batri a pa chaje nèt.
  • Ranplase batri a.
  • Ensure unit has been connected to AC power for at least 24 hours prior to test.

9. Espesifikasyon

KarakteristikDetay
Nimewo ModèlLEDR-1
MakPI BON
Materyèl LojmanWhite Thermoplastic
Kalite sous limyèLED (2 heads)
VoltageX N ACT Volts AC
Wattage2 wat
Klète98 Lumen
Efikasite49 lumen/watt
Tanperati Koulè5000 Kelvin
Kalite batriNiCAD (1 AA battery required, included)
Average Battery Life (Emergency Mode)90 minit
Kalite enstalasyonFlush miray mòn
Itilizasyon Andedan kay la / DeyòAndedan kay la sèlman
Dimansyon pwodwi (L x W x H)14.75" x 3.75" x 3.75"
Pwa atik0.01 ons
Metòd kontwòlRemote (Test Button)

10. Garanti ak sipò

The BEST LEDR-1 LED Emergency Light comes with a full manufacturer warranty. For specific warranty details, claims, or technical support, please refer to the warranty card included with your product or contact Best Lighting Products directly. Keep your purchase receipt as proof of purchase.

For assistance, please contact Best Lighting Products customer service.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.