Riello 3007839
Riello Photoelectric Cell Instruction Manual
Modèl: 3007839
Entwodiksyon
This manual provides essential information for the installation, operation, and maintenance of the Riello Photoelectric Cell, model 3007839. This component is designed for flame monitoring in various Riello burner systems and is compatible with specific analog control units. Please read this manual thoroughly before installation and use to ensure safe and proper operation.
Enfòmasyon sou Sekirite
Toujou obsève prekosyon sekirite sa yo:
- Se sèlman pèsonèl kalifye ki ta dwe fè enstalasyon ak antretyen.
- Disconnect power to the appliance before performing any installation, maintenance, or troubleshooting.
- Asire w ke tout koneksyon elektrik yo konfòm ak kòd elektrik lokal ak nasyonal yo.
- Do not modify the photoelectric cell or its wiring.
- Protect the component from excessive heat, moisture, and mechanical damage.
Konpatibilite
The Riello Photoelectric Cell (part number 3007839) is compatible with the following Riello burner models and analog control units. It replaces part numbers 3007839 and 3007857.
- Burner Models:
- BGK0.1 (3737511, 3737512, 357T1)
- RG0.R (367T1)
- RG0.1R (368T1)
- RG0.2R (358T1)
- RG0.3 (359T1)
- RG0.3R (360T1)
- RG1 (3736300, 363T1)
- RG1RK (3736250, 362T1)
- RG2D (3738000, 3738010, 3738050, 20052620, 380T1)
- RG3F (393T1)
- RG4F (396T1)
- RG5S (399T1)
- Analog Control Units for Flame Monitoring:
- 552SE (3001174)
- 553SE (3001175)
- Nòt enpòtan: This photoelectric cell is pa apwopriye for digital control unit MO550.
Enstalasyon ak Enstalasyon
The photoelectric cell is a critical component for flame detection. Proper installation is essential for safe and reliable operation.
- Dekoneksyon pouvwa: Before beginning any work, ensure the main power supply to the burner system is completely disconnected and locked out to prevent accidental startup.
- Aksè: Gain access to the existing photoelectric cell or the designated mounting location on the burner. This may involve removing covers or panels.
- Removal of Old Component (if applicable): Carefully disconnect the wiring from the old photoelectric cell. Note the orientation and connection points. Gently remove the old cell from its mounting.
- Installation of New Cell: Insert the new Riello Photoelectric Cell (3007839) into the designated mounting port. Ensure it is securely seated and oriented correctly to face the flame.
- Koneksyon fil elektrik: Connect the wiring harness of the new photoelectric cell to the corresponding terminals on the burner control unit. Refer to the burner's specific wiring diagram for precise connections. Ensure connections are tight and secure.
- Montaj sekirite: Verify that the photoelectric cell is firmly mounted and will not vibrate loose during operation.
- Reyasanblaj: Replace any covers or panels that were removed during the installation process.
- Retablisman ak Tès Kouran: Restore power to the burner system. Perform a functional test according to the burner manufacturer's instructions to confirm the photoelectric cell is detecting flame correctly and the system is operating safely.

Figure 1: Close-up of the photoelectric cell, highlighting its compact design and identification label.

Figure 2: The photoelectric cell with its integrated cable and connector, ready for electrical hookup.

Figi 3: Yon lòt view of the photoelectric cell, illustrating the cable length and connector details.
Fonksyònman Prensip
The Riello Photoelectric Cell operates as a flame sensor. When the burner ignites, the cell detects the presence of visible light emitted by the flame. This detection sends a signal to the compatible analog control unit (e.g., 552SE or 553SE), confirming flame presence and allowing the burner to continue its operation cycle. If the flame is not detected within a specified timeframe during ignition, or if it extinguishes during operation, the photoelectric cell signals the control unit to initiate a safety lockout, preventing unburned fuel accumulation and ensuring safety.
Antretyen
Regular maintenance helps ensure the longevity and reliable operation of the photoelectric cell.
- Enspeksyon: Periodically inspect the photoelectric cell and its wiring for any signs of physical damage, corrosion, or loose connections.
- Netwayaj: Si la viewing window of the photoelectric cell becomes dirty or obscured by soot, carefully clean it with a soft, lint-free cloth. Do not use abrasive cleaners or solvents. Ensure the burner is off and cooled before cleaning.
- Ranplasman: The photoelectric cell is a wear-and-tear component. If it consistently fails to detect flame or causes nuisance lockouts despite proper cleaning and troubleshooting, it may need replacement.
Depanaj
If the burner system experiences issues related to flame detection, consider the following troubleshooting steps:
| Sentòm | Kòz posib | Solisyon |
|---|---|---|
| Burner fails to ignite or goes into lockout immediately after ignition attempt. |
|
|
| Intermittent burner operation or unexpected lockouts. |
|
|
Si etap depanaj yo pa rezoud pwoblèm nan, konsilte yon teknisyen sèvis kalifye.
Espesifikasyon
| Atribi | Detay |
|---|---|
| Manifakti | Riello |
| Nimewo Modèl | 3007839 |
| ASIN | B01AO0V9XM |
| Kalite | Photoelectric Flame Sensor |
| Konpatibilite | Riello BGK, RG series burners; Analog control units 552SE, 553SE. (Not compatible with digital control unit MO550) |
| Ranplase Nimewo Pati yo | 3007839, 3007857 |
| Batri obligatwa | Non |
| Disponibilite pyès rezèv | Enfòmasyon pa disponib |
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.