Entwodiksyon
This manual provides comprehensive instructions for the installation, operation, and maintenance of the ECOELER YM2106 Wall Switch Vacancy & Occupancy Sensor. This device is designed to automatically control lighting and motor loads based on motion detection, offering energy savings and convenience. It supports both manual-on (vacancy sensor) and automatic-on (occupancy sensor) switching modes.
Enfòmasyon enpòtan sou sekirite
WARNING: RISK OF ELECTRIC SHOCK. Improper installation can lead to serious injury or death. Always turn off power at the circuit breaker before installation or servicing. Installation should be performed by a qualified electrician or in accordance with local electrical codes.
- Li tout enstriksyon anvan enstalasyon.
- Do not install with power on.
- Pou itilize andedan kay la sèlman.
- Asire w koneksyon fil elektrik yo byen fèm.
- Opere voltage: 120/277Vac, 60Hz.
- Neutral wire is not required for operation.
Kontni pake
Verifye ke tout konpozan yo prezan anvan ou kòmanse enstalasyon an:
- ECOELER YM2106 Sensor Switch
- Plak miray (1)
- Vis
- Bouchon fil elektrik
- Manyèl Enstriksyon Enstalasyon (dokiman sa a)
Espesifikasyon
| Nimewo Modèl | YM2106 |
| Voltage | 120/277Vac, 60Hz |
| Kalite Deteksyon | PIR (pasif enfrawouj) |
| Kouvèti | 180-degrees; 720-square feet |
| Anviwònman Reta Tan | 5 segonn pou rive nan 30 minit (reglabl) |
| Ambient Light Level | Adjustable (holds lighting off when natural light is sufficient) |
| Fil elektrik | Neutral wire not required |
| Kalite chaj | Incandescent, Fluorescent, LED, CFL |
| Sètifikasyon | UL Listed, Title-24 Compliant |
| Dimansyon | 4.12 x 1.69 x 1.75 pous |
| Materyèl | Plastik & Metal |
Enstriksyon Enstalasyon
Anvan ou kòmanse: Turn OFF power at the circuit breaker or fuse box. Ensure the power is completely disconnected before proceeding.
- Prepare fil elektrik yo: Carefully remove the existing wall switch from the electrical box. Identify the LINE (hot), LOAD, and GROUND wires. The ECOELER YM2106 does not require a neutral wire.
- Konekte fil yo:
- Konekte a fil nwa soti nan detèktè a rive nan LINE (hot) wire from the electrical box. Secure with a wiring cap.
- Konekte a fil wouj soti nan detèktè a rive nan Fil chaj (to the light fixture/motor) from the electrical box. Secure with a wiring cap.
- Konekte a fil vèt soti nan detèktè a rive nan Fil tè from the electrical box. Secure with a wiring cap.
- Cap off any unused wires in the electrical box, such as a neutral wire, if present.
- Monte Capteur a: Gently fold the wires into the electrical box. Insert the sensor into the electrical box and secure it with the provided screws.
- Enstale Plak Mi: Attach the decorative wall plate over the sensor and secure it.
- Retabli pouvwa: Limen kouran nan disjoncteurs a.
- Fonksyonalite tès: The green LED indicator light on the sensor will flash when motion is detected, confirming active detection.
Note: If you are unsure about any wiring steps, consult a qualified electrician.
Operasyon
The ECOELER YM2106 sensor supports two primary modes of operation: Vacancy (Manual-On) and Occupancy (Automatic-On).
Vacancy Sensor (Manual-On) Mode
In this mode, the lights/motor will only turn ON when you manually press the switch button. Once ON, the sensor will keep the lights/motor ON as long as motion is detected within its coverage area. The lights/motor will turn OFF automatically after no motion is detected for the set time delay.
Occupancy Sensor (Automatic-On) Mode
In this mode, the lights/motor will turn ON automatically when motion is detected within the sensor's coverage area. The lights/motor will remain ON as long as motion is detected and will turn OFF automatically after no motion is detected for the set time delay.
To switch between modes or adjust settings, refer to the "Configuration and Settings" section.
Konfigirasyon ak Anviwònman
The ECOELER YM2106 sensor features adjustable settings for time delay, sensitivity, and ambient light level. These adjustments are typically made via small dials or switches located on the sensor itself, often behind the wall plate.
- Reta Tan: This setting determines how long the lights/motor remain ON after the last detected motion. It is adjustable from 5 seconds to 30 minutes. Adjust clockwise for longer delays, counter-clockwise for shorter delays.
- Sansiblite: This controls the sensor's responsiveness to motion. Higher sensitivity detects smaller movements or movements at greater distances. Lower sensitivity requires more significant motion or closer proximity. Adjust as needed to prevent false triggers or missed detections.
- Ambient Light Level (Photocell): This setting allows the sensor to hold the lights/motor OFF if sufficient natural light is present in the room, even if motion is detected. This feature helps save energy by preventing artificial lighting from turning on unnecessarily. Adjust to your desired light threshold.
Consult the diagrams on the sensor unit itself for the exact location and labeling of these adjustment controls.
Antretyen
- Netwayaj: Siye lantiy detèktè a detanzantan avèk yon twal mou epi sèk pou retire pousyè oswa debri ki ka anpeche deteksyon an. Pa sèvi ak pwodui netwayaj abrazif oswa solvang.
- Enspeksyon: Regularly check the sensor and wall plate for any signs of damage or loose connections.
- Pa gen okenn pati itilizatè yo ka fè sèvis: The sensor contains no user-serviceable parts. Do not attempt to open or repair the unit.
Depanaj
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Lights/Motor do not turn ON. |
|
|
| Lights/Motor turn ON unexpectedly. |
|
|
| Lights/Motor turn OFF too quickly or too slowly. |
|
|
Garanti ak sipò
For warranty information or technical support, please contact ECOELER customer service. Retain your proof of purchase for warranty claims.
Contact information is typically found on the product packaging or the manufacturer's official websit.
Enfòmasyon sou medya yo
No product images or official product videos were provided in the source data to embed in this manual.