1. Entwodiksyon
This manual provides essential information for the safe and efficient operation of your SUNGOLDPOWER 12000W 48V Split Phase Pure Sine Wave Inverter Charger. Please read this manual thoroughly before installation and use to ensure proper function and to prevent damage to the unit or connected equipment.
1.1 Enfòmasyon sou Sekirite
WARNING: This device operates with high voltages and currents. Improper installation or use can result in serious injury, death, or equipment damage. All electrical work should be performed by qualified personnel in accordance with local electrical codes.
- Asire w ke envèstisè a enstale nan yon zòn ki byen ayere, lwen materyèl ki ka pran dife.
- Do not expose the inverter to water or excessive moisture.
- Always disconnect all power sources (AC and DC) before performing any maintenance or wiring.
- Asire bon baz nan varyateur la.
- Do not attempt to disassemble or repair the inverter yourself. Refer to qualified service personnel.
2. Pwodwi souview ak Karakteristik
The SUNGOLDPOWER 12000W 48V Inverter Charger is a robust, low-frequency pure sine wave inverter designed for off-grid power systems. It integrates an inverter, an AC battery charger, and an automatic transfer switch into a single unit.

Figi 2.1: Devan view of the SUNGOLDPOWER 12000W 48V Inverter Charger, showing the display panel.
2.1 Karakteristik kle
- Sorti pouvwa: 12,000 Watts continuous, 36,000 Watts peak for 20 seconds.
- Antre / Sòti: DC 48V input, AC 240V input, AC 120/240V split phase pure sine wave output.
- Integrated Charger: 80 Amp AC battery charger with multi-stage chaje.
- Transfè switch: Automatic transfer switch for seamless switching between AC sources (utility/generator) and battery power.
- Batri konpatibilite: Supports AGM, Gel, Lead Acid, Lithium-ion, and LiFePO4 batteries.
- Anviwònman reglabl: User-adjustable charge current (0-100%) and DIP switch settings for utility/battery priority and low voltage koupe.
- Demaraj Otomatik Jeneratè (AGS): Feature for automatic generator activation.
- Karakteristik pwoteksyon: Plis pase/ba voltage protection, over temperature protection, and overload protection.
- Siveyans Adistans: Includes a remote control with a 32-foot cable for convenient monitoring and control.
- Capteur Tanperati: Battery temperature sensor with a 32-foot cable to protect batteries from overheating during charging.
- Aplikasyon: Suitable for various applications including homes, cabins, offices, RVs, trailers, and boats.

Figure 2.2: Visual representation of the inverter's key features, including 12KW split phase output, battery temperature sensor, remote control, auto generator start, low frequency industrial grade design, and broad compatibility with appliances and batteries.
3. Pake kontni
Lè w ap debale, verifye ke tout atik ki nan lis anba a yo la epi yo pa domaje:
- SUNGOLDPOWER 12000W 48V Split Phase Inverter Charger (1 unit)
- Remote Control with 32-foot cable (1 set)
- Battery Temperature Sensor with 32-foot cable (1 set)
- Manyèl Itilizatè (dokiman sa a)

Figure 3.1: Included accessories with the SUNGOLDPOWER Inverter Charger.
4. Espesifikasyon
| Spesifikasyon | Valè |
|---|---|
| Nimewo Modèl | I12000S4812024060HCCAMSG2 |
| Pouvwa kontinyèl | 12000 Watts |
| Peak Power (20s) | 36000 Watts |
| DC Antre Voltage | 48V |
| AC Antre Voltage | 240V |
| AC Sòti Voltage | 120V / 240V Split Faz |
| Sòti Ond | Vag sinis pi |
| AC Battery Charger Current | 80 Amps |
| Dimansyon pwodwi | 27.6 x 16.5 x 7.9 pous |
| Pwa atik | 197.1 liv |
| Manifakti | SUNGOLDPOWER |
| Itilizasyon Rekòmande | Home, Office, RV, Trailer, Boat, Workshop |
| Sous pouvwa | Batri Powered |
5. Enstalasyon ak Enstalasyon
Proper installation is critical for the safety and performance of your inverter charger. Consult a qualified electrician if you are unsure about any steps.
5.1 Kote montaj
- Mount the inverter on a sturdy, non-flammable surface.
- Ensure adequate ventilation around the unit to prevent overheating. Maintain clear space around all vents.
- Avoid locations exposed to direct sunlight, high temperatures, dust, or moisture.
5.2 Koneksyon fil elektrik
Refer to the wiring diagram below for proper connection of solar panels (if applicable), MPPT solar controller, battery bank, AC input (utility or generator), and AC output to loads.

Figure 5.1: Typical application wiring diagram.
5.2.1 Koneksyon Batri DC
- Connect the 48V battery bank to the DC input terminals (positive and negative) on the inverter. Use appropriately sized cables and fuses.
- Ensure correct polarity. Reverse polarity can severely damage the unit.
- Connect the included battery temperature sensor to the battery and the designated port on the inverter.
5.2.2 Koneksyon Antre AC
- Connect the 240V AC input from your utility grid or generator to the AC input terminals.
- Ensure the AC input source is properly fused or circuit-breakered.
5.2.3 Koneksyon Sòti AC
- Connect your 120V/240V split phase loads to the AC output terminals.
- Ensure all output circuits are protected by appropriate circuit breakers.
5.2.4 Terre
- Connect the grounding terminal of the inverter to a reliable earth ground.

Figi 5.2: Koneksyon ak kontwòl panèl dèyè a.
5.3 Anviwònman DIP switch
The inverter features DIP switches to configure various operational parameters, including:
- Kalite batri: Select the appropriate battery chemistry (AGM, Gel, Lead Acid, LiFePO4, etc.) for optimized charging.
- Chaje aktyèl: Adjust the AC battery charger current from 0-100%.
- Utility/Battery Priority: Set whether the inverter prioritizes AC utility power or battery power.
- Low Voltage Koupe: Konfigirasyon DC voltage level at which the inverter will shut down to protect batteries from over-discharge.
Refer to the detailed instructions in the full user manual for specific DIP switch configurations.
6. Operasyon
6.1 Limen/Etenyen
- Asire w ke tout koneksyon an sekirite anvan ou alimante.
- Turn on the DC breaker from the battery bank first.
- Then, turn on the AC input breaker (if connecting to utility/generator).
- Finally, switch the inverter's main power switch to the "ON" position.
- To power off, reverse the sequence: Inverter OFF, AC input OFF, DC input OFF.
6.2 Kontwòl Remote
The included remote control allows for convenient monitoring of system status and basic control functions from a distance. Connect the remote control to the RJ11 port on the inverter using the provided cable.

Figure 6.1: Inverter display panel showing operational data.
6.3 Demaraj Otomatik Jeneratè (AGS)
If configured, the AGS feature will automatically start a connected generator when the battery voltage drops below a preset level, ensuring continuous power supply and battery charging.
7. Antretyen
Regular maintenance helps ensure the longevity and reliable operation of your inverter charger.
- Netwayaj: Periodically clean the exterior of the inverter with a dry cloth. Ensure vents are free from dust and debris. Do not use liquid cleaners.
- Tcheke Koneksyon: Annually inspect all electrical connections (DC and AC) for tightness and corrosion. Loose connections can cause overheating and poor performance.
- Enspeksyon batri: Regularly check your battery bank for proper voltage, electrolyte levels (for flooded batteries), and terminal cleanliness.
- Vantilasyon: Asire w ke zòn enstalasyon an rete byen ayere epi san obstak.
NAN. Depanaj
This section provides general guidance for common issues. For detailed troubleshooting steps and error codes, refer to the comprehensive user manual.
8.1 Pwoblèm komen ak solisyon
- Pa gen pwodiksyon pouvwa: Check DC battery connections, battery voltage, AC input connection, and inverter's power switch. Verify circuit breakers are not tripped.
- Alam Surcharge: Diminye chaj ki konekte a. Anjeneral, envèstisè a ap eseye rekòmanse apre yon surcharge. Si pwoblèm nan pèsiste, tcheke pou wè si gen kous sikwi nan fil elektrik chaj la.
- Over Temperature Alarm: Ensure adequate ventilation around the inverter. Clear any obstructions from cooling vents. Reduce ambient temperature if possible.
- Low Battery Voltage Alam: Check battery charge level. Ensure the AC charger is functioning or solar input is sufficient. Adjust low voltage cut-off settings if necessary (refer to DIP switch settings).
- Envèstisè a pa chaje pil yo: Verify AC input is present and stable. Check AC input breaker. Ensure battery type and charge current settings are correct via DIP switches.
If you encounter persistent issues or error codes not covered here, contact SUNGOLDPOWER technical support.
9. Garanti ak sipò
SUNGOLDPOWER provides a 12-mwa garanti for this inverter charger, covering defects in materials and workmanship under normal use.
Anplis de sa, lifetime technical service is provided by SUNGOLDPOWER to assist with any operational or technical inquiries you may have.
For warranty claims or technical assistance, please contact SUNGOLDPOWER customer service with your product model number and purchase details.
For more information, visit the official SUNGOLDPOWER websit la oubyen gade enfòmasyon kontak yo bay nan dokiman acha ou a.