AC Infinity AI-CP2H

AC Infinity CLOUDPLATE T7-N Rack Mount Fan Panel 2U

Manyèl Enstriksyon

Model: AI-CP2H | Brand: AC Infinity

Entwodiksyon

The AC Infinity CLOUDPLATE T7-N is an intelligent fan system specifically designed for cooling audio video, DJ, server, network, and IT equipment racks. Maintaining an optimal temperature for rack-mount equipment is crucial to prevent overheating, ensure consistent performance, and extend their operational lifespan. This manual provides essential information for the proper setup, operation, and maintenance of your CLOUDPLATE T7-N unit.

Enfòmasyon sou Sekirite

  • Asire ekipman pou pouvwa a voltage matches the requirements specified for the unit.
  • Do not operate the unit with damaged cords or plugs.
  • Kenbe aparèy la lwen dlo oswa imidite twòp.
  • Do not block the fan intake or exhaust vents.
  • Toujou dekonekte kouran an anvan ou fè nenpòt antretyen oswa enstalasyon.

Kontni pake

Twous konplè a gen ladan atik sa yo:

  • 1 x CLOUDPLATE T7-N 2U Fan Unit
  • 1 x Corded 6-ft Thermal Probe
  • 1 x User’s Manual (this document)
  • Rack Mount Screws
  • Kaj nwa
  • 1 x Corded 6-ft Power Supply
AC Infinity CLOUDPLATE T7-N accessories including thermal probe, power adapter, and mounting hardware.

Image: Included accessories for the CLOUDPLATE T7-N, showing the thermal probe, power adapter, and mounting screws.

Pwodwi souview

The CLOUDPLATE T7-N is housed in a solid anodized aluminum construction, occupying two rack units (2U) of space. It features CNC-machined detailing for a professional appearance. This model is designed for intake airflow, drawing cooler air into the rack, and should typically be positioned near the bottom.

The unit incorporates four custom-engineered dual-ball bearing fans, rated for 67,000 hours of operation and certified by CE and RoHS. These fans utilize a PWM motor and spiral-curved blade design to maximize airflow at lower speeds while minimizing noise levels.

Entèn view of a CLOUDPLATE fan with dual-ball bearing PWM motor.

Imaj: Detaye view of a dual-ball bearing fan with PWM motor, designed for high performance and minimal noise.

Enstalasyon

  1. Montaj etajè: Identify a 2U space in your 19-inch equipment rack. Use the provided rack mount screws and cage nuts to securely install the CLOUDPLATE T7-N unit. Ensure the unit is flush with the rack rails.
  2. Thermal Probe Connection: Connect the corded 6-ft thermal probe to the designated port on the unit. Position the probe within the rack where you want to monitor the temperature, typically near heat-generating equipment.
  3. Koneksyon pouvwa: Connect the provided 6-ft power supply to the unit and then to a standard electrical outlet.
  4. Premye limen: Once all connections are secure, the unit will power on, and the LCD display will activate.
AC Infinity CLOUDPLATE T7-N installed in a rack with other equipment.

Image: The CLOUDPLATE T7-N unit seamlessly integrated into a standard equipment rack.

Diagram showing airflow in a rack with AC Infinity CLOUDPLATE fans.

Image: Illustrates the intake airflow design, with cool air entering from the bottom and warm air exiting the top of the rack.

Enstriksyon Operasyon

The CLOUDPLATE T7-N features an LCD digital controller with a programmable thermostat and automated speed control. This allows the system to react to varying temperatures efficiently.

  • Mòd SMART: This mode automatically adjusts the fan speed based on the temperature detected by the thermal probe. You can set a target temperature and a buffer, and the fans will increase speed as the temperature rises above the target plus buffer.
  • Mòd manyèl: Manually select one of six available fan speeds to maintain a constant airflow, regardless of temperature.
  • Alam Tanperati: The controller can be set to trigger alarm warnings if the temperature exceeds a user-defined threshold.
  • Fan Failure Triggers: The system monitors fan operation and can alert you in case of a fan failure.
  • Montre Anviwònman: Adjust screen brightness with three available settings. The display also features a lock function to prevent accidental changes.
  • Memwa backup: Settings are saved even if power is interrupted.
  • Pò ekspansyon: An expansion port at the rear allows for daisy-chaining additional CLOUDPLATE units or AC Infinity rack roof dual-fan kits to share the same control programming for enhanced cooling.
Close-up of the AC Infinity CLOUDPLATE T7-N intelligent programming display.

Image: The intelligent programming display showing current temperature, set temperature, fan speed, and buffer settings.

Video: An official product video demonstrating the features and functionality of the CLOUDPLATE Series rack mount cooling fan systems.

Antretyen

Regular maintenance ensures optimal performance and longevity of your CLOUDPLATE T7-N unit.

  • Netwayaj: Periodically inspect the fan grilles and blades for dust accumulation. Use a soft brush or compressed air to gently clean the fans and vents. Ensure the unit is powered off and unplugged before cleaning.
  • Thermal Probe: Keep the thermal probe clean and free from obstructions to ensure accurate temperature readings.
  • Koneksyon: Periodically check all cable connections (power, thermal probe, expansion) to ensure they are secure.

Depanaj

PwoblèmKòz posibSolisyon
Fans not spinning / Display offPa gen kouran, koneksyon ki lach, pwoblèm adaptè kouran.Check power cable connection to unit and outlet. Ensure outlet is functional. Try a different power adapter if available.
Lekti tanperati ki pa egzakThermal probe improperly placed or damaged.Ensure thermal probe is securely connected and positioned correctly. Avoid placing it directly on hot components. Check for physical damage to the probe.
Fans running too fast/slow in SMART modeIncorrect temperature settings (SET, BUFFER).Adjust the SET temperature and BUFFER values on the controller to match your desired cooling profile.
Inite a fè bwiHigh fan speed, dust accumulation, fan bearing issue.Lower the fan speed setting. Clean the fan blades and grilles. If noise persists at low speeds, contact support.
Alarm warning displayedTemperature exceeded alarm threshold, fan failure.Check the current temperature. If it's too high, increase fan speed or check for obstructions. If it's a fan failure warning, inspect fans for operation.

Espesifikasyon

KarakteristikDetay
ModèlAI-CP2H
Espas etajè2U
DesignKonsomasyon
Total Airflow50 a 220 CFM
Total Bri10 a 36 dBA
Presyon estatik2.56 mm-H2O
Opere Voltage12V DC
Pouvwa10 W
Kouran0.83 A
Mi Adaptè Antre100 a 240V AC
Operasyon Imidite35 a 85% RH
Tanperati Fonksyònman0 a 158 ° F (0 a 70 ° C)
Fanatik BEARINGSDoub boul
L10 Life Expectancy67,000 èdtan
Dimansyon total19.0 x 3.5 x 1.5 pous (48.3 x 8.9 x 3.8 cm)
MateryèlAliminyòm
Diagram showing dimensions and key specifications of the AC Infinity CLOUDPLATE T7-N.

Image: Visual representation of the unit's dimensions and core performance specifications.

Enfòmasyon sou Garanti

Specific warranty details for the AC Infinity CLOUDPLATE T7-N are typically provided with the product packaging or can be found on the official AC Infinity website. Please refer to these resources for the most current and comprehensive warranty terms and conditions.

Sipò

Pou plis asistans, sipò teknik, oubyen pou view additional product documentation, please visit the official AC Infinity website. You may find FAQs, troubleshooting guides, and contact information for customer service there.

AC infini Websit: www.acinfinity.com

© 2023 AC Infinity. Tout dwa rezève.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.