CATA 01055000

CATA X-Mart 12 Matic Inox Exhaust Fan User Manual

Modèl: 01055000

1. Entwodiksyon

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your CATA X-Mart 12 Matic Inox Exhaust Fan. Please read these instructions carefully before using the appliance and retain them for future reference.

The CATA X-Mart 12 Matic Inox is a recessed perimetral bathroom exhaust fan designed for effective ventilation. It features a unique automatic shutter system, a removable screw-less front for easy cleaning, and a streamlined design for improved airflow.

2. Enfòmasyon sou Sekirite

WARNING: Failure to follow these safety instructions may result in electric shock, fire, or personal injury.

  • Asire w ke ekipman pou kouran an dekonekte anvan enstalasyon, antretyen oswa netwayaj.
  • Enstalasyon an dwe fèt pa yon elektrisyen kalifye, dapre tout kòd elektrik lokal ak nasyonal yo.
  • Do not install the fan in areas where flammable or explosive gases may be present.
  • Aparèy sa a pa fèt pou itilize pa moun (ki gen ladan timoun) ki gen kapasite fizik, sansoryèl oswa mantal redwi, oswa ki pa gen eksperyans ak konesans, sof si yo te bay sipèvizyon oswa enstriksyon konsènan itilizasyon aparèy la pa yon moun ki responsab sekirite yo. .
  • Kenbe timoun yo lwen aparèy la.
  • Do not operate the fan if any part is damaged. Contact qualified service personnel for repairs.
  • Asire bon baz tè nan aparèy la.
  • The fan is designed for indoor use only, specifically for bathrooms.

3. Pake kontni

Verifye ke tout konpozan yo prezan epi yo pa domaje anvan ou kontinye ak enstalasyon an.

  • 1 x CATA X-Mart 12 Matic Inox Exhaust Fan Body
  • 1 x Manyèl Enstriksyon (dokiman sa a)

Note: Additional mounting hardware (screws, wall plugs, ducting) may be required and are typically not included.

4. Spécifications pwodwi

CATA X-Mart 12 Matic Inox Technical Specifications
KarakteristikSpesifikasyon
MakCATA
Nimewo Modèl01055000
Konsepsyon fanatik elektrikFanatik echapman
KoulèINOX
Sous pouvwaElektrik
Kalite chanmTwalèt
Karakteristik espesyalAutomatic Shutter System
Nivo bri40 Desibèl
Wattage20 Watts
Fini KaliteNerjaveèi asye
Pwa atik0.88 Kilogram
Dimansyon atik (LxWxH)17 x 13.9 x 17 santimèt
Kapasite pou aspirasyon190 m³/h
Dyamèt120 mm

Performance curve for CATA X-Mart Matic 12 exhaust fan, showing pressure (Pa) versus airflow (m³/h).Figure 4.1: Performance curve for the X-Mart Matic 12, illustrating the relationship between static pressure and airflow volume.

5. Enstalasyon ak Enstalasyon

The CATA X-Mart 12 Matic Inox fan is designed for fully recessed installation in walls or ceilings. It features an easy screw-less installation system.

5.1 Chèk Pre-Enstalasyon

  • Ensure the installation location is suitable for an exhaust fan, considering ventilation requirements and proximity to moisture sources.
  • Verify that the wall or ceiling opening matches the fan's dimensions. Refer to the dimension diagram below.
  • Confirm that the electrical supply meets the fan's requirements (20 Watts, standard household voltagak).
  • Gather necessary tools: screwdriver, drill, measuring tape, wire strippers, safety gloves, safety glasses.

Dimensional drawing of CATA X-Mart Matic exhaust fans, showing front, side, and top views with measurements for models 10, 12, and 15. Model 12 dimensions are highlighted.Figure 5.1: Dimensional drawing for X-Mart Matic series. For Model 12, refer to the row with B=170mm, C=101mm, and ØA=118mm.

5.2 Etap enstalasyon yo

  1. Dekonekte pouvwa: Koupe kouran prensipal la nan zòn enstalasyon an nan disjonktè a.
  2. Prepare Ouvèti a: Create or verify an opening in the wall or ceiling that accommodates the fan's dimensions (approximately 118mm diameter for the duct, and 170x170mm for the main body recess).
  3. Mount Fan Body: Insert the fan body into the prepared opening. The screw-less installation system allows for easy securing. Ensure it is flush with the surface.
  4. Koneksyon elektrik: Connect the electrical wiring to the fan's terminal block. Ensure correct polarity (Live, Neutral, Earth) and secure all connections. Refer to local electrical codes.
  5. Attach Ducting (if applicable): If connecting to an external duct, secure the ducting to the fan's outlet using appropriate clamps oswa kasèt.
  6. Install Front Cover: Attach the removable screw-less front cover to the fan body. Ensure it clicks securely into place.
  7. Retabli pouvwa: Yon fwa enstalasyon an fini epi tout koneksyon yo byen fèm, retabli kouran an nan disjonktè a.
  8. Operasyon tès: Turn on the fan to ensure it operates correctly. Observe the automatic front opening and airflow.

Devan view of the CATA X-Mart 12 Matic Inox exhaust fan, showing its brushed stainless steel finish, central indicator light, and 'X-MART cataC' branding.Figure 5.2: CATA X-Mart 12 Matic Inox Exhaust Fan, front view.

6. Operasyon Enstriksyon

The CATA X-Mart 12 Matic Inox Exhaust Fan is designed for straightforward operation.

  • Limen/Etenyen: The fan is typically connected to a light switch or a dedicated fan switch in the bathroom. Flipping the switch to the 'ON' position will activate the fan.
  • Automatic Shutter: Upon activation, the fan's automatic front opening mechanism will engage, allowing air to flow. When the fan is turned off, the shutter will close to prevent backdraft and maintain insulation.
  • Limyè Endikatè Operasyon: A small indicator light on the front panel will illuminate when the fan is operating, providing a visual confirmation of its status.
  • Airflow: The fan will draw stale, humid air from the room and expel it through the ducting system, improving air quality and reducing moisture.

7. Antretyen

Regular cleaning and maintenance will ensure optimal performance and longevity of your exhaust fan.

7.1 Netwaye fanatik la

  1. Dekonekte pouvwa: Always turn off the power supply to the fan at the circuit breaker before cleaning.
  2. Retire kouvèti devan: The fan features a removable screw-less front for easy access. Gently unclip or detach the front cover.
  3. Kouvèti pwòp: Wash the front cover with mild soap and water. Rinse thoroughly and dry completely before reattaching.
  4. Clean Fan Blades and Interior: Use a soft cloth or a vacuum cleaner with a brush attachment to carefully remove dust and debris from the fan blades, motor housing, and interior surfaces. Do not use abrasive cleaners or allow water to enter the motor.
  5. Retache kouvèti devan an: Once all parts are clean and dry, securely reattach the front cover.
  6. Retabli pouvwa: Vire ekipman pou pouvwa a tounen sou.

Recommended cleaning frequency: Every 3-6 months, or more often in dusty or high-humidity environments.

NAN. Depanaj

If you encounter issues with your CATA X-Mart 12 Matic Inox Exhaust Fan, refer to the following common problems and solutions:

PwoblèmKòz posibSolisyon
Vantilatè a pa limen.Pa gen kouran; fil elektrik ki lach; switch ki gen pwoblèm.Check circuit breaker. Ensure switch is ON. Verify wiring connections (consult an electrician if unsure).
Fan is noisy or vibrating.Loose mounting; debris in fan blades; motor issue.Ensure fan is securely mounted. Disconnect power and clean fan blades. If noise persists, contact service.
Pòv koule lè.Blocked ducting; dirty fan blades; automatic shutter not opening fully.Clean fan blades and interior. Check ducting for obstructions. Ensure shutter mechanism is free of debris.
Automatic shutter not opening/closing.Obstruction; mechanism fault.Disconnect power and carefully check for any physical obstructions around the shutter mechanism. Clean if necessary.

Si pwoblèm nan pèsiste apre ou fin eseye solisyon sa yo, tanpri kontakte pèsonèl sèvis ki kalifye.

9. Garanti ak sipò

CATA products are manufactured to high-quality standards. For information regarding warranty coverage, terms, and conditions, please refer to the warranty card included with your purchase or visit the official CATA websit.

For technical support, spare parts, or service inquiries, please contact your local CATA distributor or authorized service center. When contacting support, please have your model number (01055000) and purchase details readily available.

© 2023 CATA. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.