Casella CEL-246/K1

Casella CEL-246/K1 Digital Logging Integrating Sound Level Meter Type 2 Kit User Manual

Model: CEL-246/K1

Brand: Casella

1. Entwodiksyon

This manual provides comprehensive instructions for the proper use, setup, operation, and maintenance of the Casella CEL-246/K1 Digital Logging Integrating Sound Level Meter Type 2 Kit. This device is designed for precise sound level measurements, incorporating Digital Signal Processing (DSP) technology for accurate and reliable data.

The CEL-246/K1 offers a wide measurement range, selectable frequency weightings (A and C), and time responses (Slow, Fast, Impulse). It features a non-decaying maximum hold function and a clear display showing current, highest, and average noise levels, along with a time history trend. Data logging capabilities are available via a USB output port.

2. Sa ki enkli

The Casella CEL-246/K1 Kit includes the following components:

  • One (1) Casella CEL-246/K1 Sound Level Meter
  • One (1) Acoustic Calibrator
  • One (1) Foam Windscreen
  • Yon (1) ka pote
  • One (1) Calibration Certificate
  • Three (3) AA Batteries

3. Enstalasyon

3.1 Enstalasyon batri

  1. Locate the battery compartment on the rear of the sound level meter.
  2. Louvri kouvèti lòj la.
  3. Mete twa (3) pil AA, asire w polarite a kòrèk (+/-).
  4. Fèmen kouvèti lòj batri a byen.

3.2 Attaching the Foam Windscreen

Gently slide the foam windscreen over the microphone at the top of the sound level meter. This helps to reduce wind noise during outdoor measurements.

3.3 Premye pouvwa sou

Press the power button to turn on the device. The display will illuminate, showing the current measurement mode and readings.

Casella CEL-246/K1 Digital Logging Integrating Sound Level Meter with foam windscreen attached

An image showing the Casella CEL-246/K1 Digital Logging Integrating Sound Level Meter. The device is blue and grey, with a display screen showing measurement data and a graph. A black foam windscreen is attached to the top microphone.

4. Operasyon Enstriksyon

4.1 Operasyon debaz

The CEL-246/K1 features simple two-button operation for ease of use. Refer to the on-screen prompts and the full user guide for detailed button functions.

4.2 Frequency Weighting

The meter supports two frequency weighting scales:

  • A-Weighting: Attenuates lower frequencies to approximate the human ear's response, which is most sensitive between 3000 and 4000 Hz. Use for general noise measurements.
  • C-Weighting: Reads all frequencies more uniformly, providing a better response to higher frequencies than A-weighting. Useful for pinpointing problems when A-weighted readings are very high.

4.3 Time Weighting

Selectable time responses include:

  • Ralanti: Provides a slower response, suitable for measuring steady noise levels.
  • Vit: Offers a quicker response, ideal for capturing fluctuating noise levels.
  • Enpilsyon: Designed for very short, sharp noise events.

4.4 Maximum Hold Feature

The non-decaying maximum hold feature captures and displays the highest sound pressure level detected until manually reset. This is useful for identifying peak noise events.

4.5 Data Logging and USB Output

The meter includes a USB output port for simple data logging. Connect the device to a PC to download stored data or for real-time data analysis using the optional software package. Data can be exported in spreadsheet format for further analysis.

4.6 Auto Calibration

The CEL-246/K1 supports auto calibration at a selected decibel level using the included acoustic calibrator. Refer to the full user guide for detailed calibration procedures to ensure measurement accuracy.

5. Antretyen

5.1 Netwayaj

Wipe the meter's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the device.

5.2 Ranplasman batri

Replace batteries when the low battery indicator appears on the display. Always use three (3) new AA batteries of the same type.

5.3 Depo

When not in use for extended periods, remove the batteries to prevent leakage. Store the meter in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.

5.4 Kalibrasyon

Regular calibration is crucial for maintaining measurement accuracy. Use the provided acoustic calibrator according to the instructions in Section 4.6 and the full user guide. It is recommended to calibrate the device before each critical measurement session.

NAN. Depanaj

6.1 Meter Not Powering On

  • Check if the batteries are correctly inserted with proper polarity.
  • Ranplase ak pil AA fre.
  • Asire w ke bouton pouvwa a peze byen fèm.

6.2 Lekti ki pa egzak

  • Perform an auto calibration using the acoustic calibrator.
  • Ensure the foam windscreen is properly attached to minimize wind noise.
  • Verify that the correct frequency (A or C) and time weighting (Slow, Fast, Impulse) are selected for your measurement environment.
  • Check for any physical damage to the microphone or device.

6.3 Data Logging Issues

  • Asire w kab USB a byen konekte ak ni kontè a ni ak òdinatè a.
  • Verify that the necessary software drivers are installed on your PC.
  • Consult the software manual for specific data transfer instructions.

7. Espesifikasyon

KarakteristikSpesifikasyon
Nimewo ModèlCEL-246/K1
Ranje Mezi30 a 130 dB
Pwa frekansA oswa C
Pondération tanSlow, Fast, Impulse
EkspozisyonCurrent, Highest, Average Noise Level, Time History Trend
Pòv Sòti aUSB for data logging
Sous pouvwa3 x AA pil
Dimansyon pake17 x 12.5 x 4 pous
Pwa pake3.9 liv
Peyi orijinWayòm Ini
ManifaktiCole-Parmer

8. Garanti ak sipò

For warranty information and technical support, please refer to the documentation provided with your purchase or contact Casella customer service directly. Keep your purchase receipt as proof of purchase.

Manufacturer: Cole-Parmer

© 2024 Casella. All rights reserved.