TENMARS TM-195

TENMARS TM-195 3-Axis RF Field Strength Meter Instruction Manual

Modèl: TM-195

1. Entwodiksyon

The TENMARS TM-195 is a 3-axis high-frequency electromagnetic field strength meter designed for measuring and monitoring Radio Frequency (RF) electromagnetic fields. It is capable of measuring frequencies ranging from 50MHz to 3.5GHz. This manual provides essential information for the safe and effective operation of your device.

2. Enfòmasyon sou Sekirite

Tanpri li epi konprann tout enstriksyon sekirite yo anvan ou itilize aparèy la.

  • Pa eseye repare oswa modifye aparèy la. Konfye tout antretyen bay pèsonèl kalifye.
  • Ensure the battery compartment is securely closed during operation.
  • Evite ekspoze aparèy la nan tanperati ekstrèm, imidite, oswa limyè solèy la dirèk.
  • Kenbe aparèy la lwen gwo chan mayetik.
  • Jete pil yo selon règleman lokal yo.

3. Pwodwi souview

The TM-195 features a compact design with an integrated 3-axis isotropic sensor for comprehensive RF field strength measurements.

TENMARS TM-195 3-Axis RF Field Strength Meter with carrying case

Figi 1: TENMARS TM-195 RF Field Strength Meter and Carrying Case. The meter features an orange spherical sensor at the top, a green LCD display showing '360.4 mV/m' and '0945 XYZ', and control buttons below the display. A black carrying case is visible to the right.

3.1. Eleman yo

  • 3-Axis Isotropic Sensor: Spherical sensor for comprehensive field detection.
  • Ekspozisyon LCD: 4-1/2 digits, maximum reading 19999, shows measured values, units, and status indicators.
  • Bouton kontwòl: For power, mode selection, unit change, data hold, alarm settings, and data memory.
  • Lòj batri: Located at the rear for 9V battery.

3.2. Montre Endikatè

  • XYZ: Indicates triaxial measurement mode.
  • mV/m, V/m, µA/m, mA/m, µW/m², mW/m², µW/cm²: Inite mezi.
  • MAX / MOYEN: Maximum and Average value indicators.
  • RETE: Data hold function active.
  • ALAM: Alarm function active.
  • Ikon batri: Endike nivo batri a.

4. Enstalasyon

4.1. Enstalasyon batri

  1. Louvri kouvèti lòj batri a sou do aparèy la.
  2. Insert a new 9V battery (NEDA 1604, IEC 6F22, or JIS 006P), observing polarity.
  3. Fèmen kouvèti lòj batri a byen.

4.2. Premye Limen

Peze a Pouvwa button (labeled with a circle and vertical line) to turn on the device. The display will illuminate and show the current RF field strength.

5. Operasyon Enstriksyon

5.1. Power On/Off

  • Pou pouvwa sou, peze la Pouvwa bouton.
  • Pou koupe pouvwa a, peze epi kenbe Pouvwa bouton pou apeprè 2 segonn.

5.2. Measurement Modes (MAX/AVG)

Peze a MAX/AVG button to cycle through measurement display modes:

  • Instantaneous Value: Displays the current real-time measurement.
  • Maximum Value (MAX): Displays the highest value recorded since power-on or reset.
  • Average Value (AVG): Displays the average value recorded over time.
  • Maximum Average Value (MAX AVG): Displays the maximum of the averaged values.

5.3. Seleksyon Inite

Peze a UNIT/ENTER button to change the measurement unit. Available units include:

  • mV/m (millivolts per meter)
  • V/m (volts per meter)
  • µA/m (microamperes per meter)
  • mA/m (milliamperes per meter)
  • µW/m² (microwatts per square meter)
  • mW/m² (milliwatts per square meter)
  • µW/cm² (microwatts per square centimeter)

5.4. Data Hold (HOLD/ALARM)

Peze a HOLD/ALARM Peze bouton an yon ti moman pou bloke lekti aktyèl la sou ekran an. Peze ankò pou lage li.

5.5. Fonksyon alam

Pou fikse papòt alam la:

  1. Peze epi kenbe la HOLD/ALARM button for approximately 2 seconds to enter alarm setting mode.
  2. Sèvi ak la MAX/AVG epi REC/TIME bouton pou ajiste valè papòt la.
  3. Peze UNIT/ENTER konfime epi sove anviwònman an.
  4. The audible buzzer alarm will activate if the measured value exceeds the set threshold.

5.6. Data Memory (XYZ/MEM)

The device supports manual storage of up to 200 data sets.

  1. Pou sove yon lekti, peze bouton an XYZ/MEM button briefly. The current reading will be stored.
  2. To recall stored data, press and hold the XYZ/MEM button for approximately 2 seconds. Use the MAX/AVG epi REC/TIME buttons to navigate through stored records.
  3. Peze UNIT/ENTER to exit data recall mode.

5.7. Calibration Factor (CAL) Adjustment

The calibration factor can be adjusted if necessary. Refer to the SET button and its associated menu for this advanced setting. This feature allows for fine-tuning the meter's response.

5.8. Auto Power Off

The device has an adjustable auto power-off function. The default time is 15 minutes. To adjust this setting:

  1. Peze epi kenbe la SET bouton pou antre nan meni an paramèt.
  2. Navigate to the auto power-off option using the MAX/AVG or REC/TIME bouton.
  3. Sèvi ak la MAX/AVG epi REC/TIME buttons to set the desired time (0 to 99 minutes).
  4. Peze UNIT/ENTER to confirm and save. Setting to 0 disables auto power-off.

6. Antretyen

  • Netwaye aparèy la avèk yon twal mou epi sèk. Pa sèvi ak pwodui netwayaj abrazif oswa solvan.
  • If the device will not be used for an extended period, remove the battery to prevent leakage.
  • Sere aparèy la nan yon kote ki fre epi sèk, lwen limyè solèy dirèk ak tanperati ekstrèm.

NAN. Depanaj

  • Aparèy la pa limen: Tcheke enstalasyon batri a epi asire w ke batri a gen ase chaj. Ranplase l si sa nesesè.
  • Inconsistent readings: Ensure the device is held steady and away from large metallic objects or other strong RF sources that might interfere with measurements. Verify the selected unit is appropriate for the measurement range.
  • Alam pa sonnen: Check if the alarm function is enabled and the threshold is set correctly.
  • Ekran an vid oswa li pa klere byen: Ranplase batri a.

8. Espesifikasyon

KarakteristikSpesifikasyon
Gamme frekans50MHz pou 3.5GHz
EkspozisyonLiquid-crystal (LCD), 4-1/2 digits, max reading 19999
Kalite MeziDigital, Triaxial, Isotropic
Rezolisyon ekspozisyon0.1mV/m, 0.1µA/m, 0.001µW/m², 0.001µW/cm²
Inite yomV/m, V/m, µA/m, mA/m, µW/m², mW/m², µW/cm²
Alam ki tandeBuzzer, adjustable threshold
Mete TanTypically 1.5s (0 to 90% measurement value)
Sample Rate1.5 fwa pa segonn
Done memwa200 data sets (manual)
Calibration Factor (CAL)Reglabl
Kalite batri9V NEDA 1604, IEC 6F22 or JIS 006P
Lavi batriApeprè 15 èdtan
Auto Power OffDefault 15 minutes, adjustable 0~99 minutes
Tanperati Fonksyònman0°C a +50°C (32°F a 122°F)
Operasyon Imidite25% a 75% RH
Tanperati Depo-10°C a +60°C (14°F a 140°F)
Depo Imidite0% a 80% RH
Dimansyon6.3 x 7.68 x 2.36 pous (160 x 195 x 60 mm)
Pwa0.44 Pounds (approx. 7 ounces / 200g)

9. Garanti ak sipò

For warranty information and technical support, please refer to the documentation provided with your purchase or contact TENMARS customer service. Keep your purchase receipt as proof of purchase.

TENMARS TM-195 Instruction Manual | © 2024 TENMARS. All rights reserved.

Manyèl sa a ka chanje san avètisman.