1. Entwodiksyon
This manual provides detailed instructions for the installation, operation, and maintenance of your Hager EK570 battery-powered weekly thermostat. Please read this guide thoroughly before use to ensure proper function, safety, and to maximize the benefits of its programmable features. Keep this manual for future reference.
2. Enfòmasyon sou Sekirite
- Always disconnect power to the heating system before attempting any installation or maintenance.
- Installation should only be performed by a qualified electrician or competent person.
- Do not expose the thermostat to extreme temperatures, direct sunlight, high humidity, or water.
- Use only LR6 (AA) batteries as specified. Do not mix old and new batteries or different types of batteries.
- Kenbe aparèy la lwen timoun yo.
- Do not attempt to open or repair the thermostat yourself. Refer to qualified service personnel.
3. Pake kontni
Verifye ke tout atik yo prezan nan pakè ou a:
- Hager EK570 Thermostat Unit
- 2 x LR6 (AA) Batteries
- Vis ak ploge miray pou monte (si sa aplikab)
- Manyèl itilizatè sa a
4. Pwodwi souview
Familiarize yourself with the components of your Hager EK570 thermostat:

Figi 1: Devan view of the Hager EK570 thermostat. The device features a clear LCD display at the top, two square buttons below the display, and a central control cluster at the bottom with '-', 'OK', and '+' buttons.
- Ekspozisyon LCD: Shows current temperature, time, day, operating mode, and program status.
- Bouton kontwòl: Used for navigating menus, adjusting settings, and selecting modes. Typically includes 'Mode', 'Set', 'Up', 'Down', and 'OK' buttons.
- Lòj batri: Sitiye nan dèyè inite a.
5. Enstalasyon
5.1. Enstalasyon batri
- Remove the back cover of the thermostat.
- Insert the 2 x LR6 (AA) batteries, ensuring correct polarity (+/-).
- Replace the back cover. The display should now activate.
5.2. Enstalasyon tèmosta a
The Hager EK570 is designed for surface mounting.
- Chwazi yon bon kote sou yon mi enteryè, lwen limyè solèy dirèk, kouran lè, ak sous chalè (pa egzanp, radyatè, limyè).amps). The recommended height is approximately 1.5 meters from the floor.
- Carefully detach the front part of the thermostat from its base plate.
- Mark the drilling points on the wall using the base plate as a template.
- Fè twou epi mete ploge miray la.
- Secure the base plate to the wall using the provided screws.
- Connect the heating system wires to the terminals on the base plate according to the wiring diagram provided with your heating system. Ensure all connections are secure and correct.
- Reattach the front part of the thermostat to the base plate, ensuring it clicks securely into place.
5.3. Anviwònman Inisyal yo (Lè ak Dat)
Upon first power-up or after battery replacement, you may need to set the current time and day.
- Press the 'SET' or 'MODE' button to enter the settings menu.
- Use the '+' or '-' buttons to navigate to 'Time' or 'Date' settings.
- Press 'OK' to confirm and then use '+' or '-' to adjust the values (hour, minute, day, month, year).
- Press 'OK' to save each setting and exit the menu.
6. Operasyon Enstriksyon
The Hager EK570 offers various operating modes and programming options to optimize your heating.
6.1. Chwazi Mòd Operasyon yo
Tèmosta a sipòte mòd sa yo:
- Mòd konfò: Maintains a comfortable temperature (e.g., 21°C) during occupied periods.
- Redwi mòd: Maintains a lower, energy-saving temperature (e.g., 18°C) during unoccupied periods or at night.
- Mòd pwoteksyon Frost: Maintains a minimum temperature (e.g., 5°C) to prevent pipes from freezing.
- Mòd manyèl: Allows you to set a constant temperature that overrides any programmed schedule.
- Mòd jou ferye: Maintains a specific temperature for an extended period (e.g., during vacation).
To switch between modes, press the 'MODE' button repeatedly until the desired mode is displayed.
6.2. Adjusting Temperature Setpoint
In any operating mode (except Frost Protection), you can temporarily adjust the temperature setpoint:
- Use the '+' or '-' buttons to increase or decrease the desired temperature.
- The new setpoint will be active until the next programmed event or until you manually change it again. This is known as a temporary override.
6.3. Pwogramasyon chak semèn
The EK570 is a weekly programmable thermostat, allowing you to set up to 48 program steps per day across 4 setpoints (Comfort, Reduced, etc.). It comes with 3 pre-recorded programs and 1 free program for customization.
- Press the 'PROG' or 'SET' button to enter programming mode.
- Use '+' or '-' to select the day of the week you wish to program (e.g., Monday, Tuesday, etc.).
- Press 'OK' to confirm the day.
- The display will show the first program period. Use '+' or '-' to set the start time and then 'OK'.
- Next, select the desired operating mode (Comfort, Reduced, etc.) for this period using '+' or '-' and confirm with 'OK'.
- Repeat steps 4 and 5 for all desired program periods for that day.
- You can copy programs from one day to another if needed (refer to specific instructions in the full manual for this feature).
- Exit programming mode by pressing 'PROG' or 'MODE' button.
7. Antretyen
7.1. Netwayaj
Netwaye tèmosta a casing with a soft, dry cloth. Do not use abrasive cleaners, solvents, or chemical agents, as these can damage the plastic and electronic components.
7.2. Ranplasman batri
The thermostat is powered by 2 x LR6 (AA) batteries. When the battery symbol appears on the display, or if the display becomes dim, it is time to replace the batteries.
- Remove the back cover of the thermostat.
- Retire ansyen pil yo.
- Insert new 2 x LR6 (AA) batteries, observing correct polarity.
- Ranplase kouvèti dèyè a.
The thermostat has a power reserve of approximately 10 minutes, allowing for battery replacement without losing programmed settings, provided the replacement is done promptly.
NAN. Depanaj
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Ekran an vid oswa li fèb. | Pil yo fèb oswa yo pa byen mete. | Replace batteries with new LR6 (AA) batteries, ensuring correct polarity. |
| Tèmosta a pa kontwole chofaj la. | Incorrect wiring; heating system fault; thermostat in 'OFF' or 'Frost Protection' mode. | Check wiring connections (consult a professional); verify heating system power; ensure thermostat is in an active heating mode (Comfort, Reduced, Manual). |
| Lekti tanperati a sanble pa egzak. | Thermostat location is affected by drafts, direct sunlight, or heat sources. | Relocate the thermostat to a more suitable position, away from external influences. |
| Cannot program the thermostat. | Incorrect programming steps followed; thermostat locked. | Refer to Section 6.3 for programming instructions. Check if a child lock feature is active (consult full manual). |
9. Espesifikasyon
| Karakteristik | Spesifikasyon |
|---|---|
| Modèl | EK570 |
| Pwovizyon pou pouvwa | 2 x LR6 (AA) Batteries (included) |
| Setpoint Adjustment Range | 5 °C a 30 °C |
| Tanperati Fonksyònman | 0 °C a 45 °C |
| Tanperati Depo / Transpò | -25 °C a 70 °C |
| Kalite ekspozisyon | LCD ak ekleraj |
| Kalite revèy | Thermostat dijital |
| Kalite Capteur | Elektwonik |
| Kalite aliye | Sifas Mounting |
| Kalite tèminal | 1 a 1.5 mm² |
| Rated Operating Current (AC1) | 5 A |
| Kapasite kraze | 5A / 250V |
| IP Pwoteksyon Rating | IP30 |
| Pouvwa Rezèv | 10 minit |
| Ecodesign Class | 4 |
| Dimansyon (apwoksimatif) | 97 mm (wotè) x 70 mm (lajè) x 30 mm (pwofondè) |
| Pwa (apwoksimatif) | 340 grams (including packaging) |
10. Garanti ak sipò