This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Beghelli BEG4103 11W LED Emergency Ceiling Light. Please read these instructions carefully before installation and retain them for future reference.
2. Enstriksyon Sekirite
- Sekirite elektrik: Installation must be performed by a qualified electrician in accordance with all local and national electrical codes. Always disconnect power at the circuit breaker before installation, maintenance, or servicing.
- Entegrite pwodwi: Do not modify or alter the product in any way. Use only original Beghelli replacement parts if necessary.
- Anviwònman: This fixture is designed for indoor use. Ensure the operating environment is within the specified temperature and humidity ranges. The standard version has an IP40 rating, while a specific kit offers IP66 protection.
- Manyen: Handle the product with care to avoid damage to the LED components or housing.
3. Pwodwi souview
The Beghelli BEG4103 is an 11W LED emergency ceiling light designed for safety signaling and emergency illumination. It features an independent LED emergency lighting system. The fixture is available in various configurations, including surface mount, recessed mount, and a version with an IP66 kit for enhanced protection.

Figure 3.1: Beghelli BEG4103 11W LED Emergency Ceiling Light.
Karakteristik kle yo enkli:
- Emergency and safety signaling lighting.
- Independent LED emergency lighting devices.
- 11 Watts LED power.
- Modern style with glass and polycarbonate materials.
- Touch control method for testing or specific functions.
4. Enstalasyon ak Enstalasyon
The Beghelli BEG4103 offers versatile installation options, including surface mount (versione a plafone), recessed mount (versione a incasso), and a version with an IP66 kit for increased ingress protection. Refer to the technical drawing below for dimensions and mounting details.

Figure 4.1: Technical drawing with dimensions for Beghelli BEG4103 in surface mount, recessed mount, and IP66 kit versions.
4.1. Etap Enstalasyon Jeneral yo
- Preparasyon: Ensure power is disconnected at the main circuit breaker. Unpack the fixture and inspect for any damage.
- Kote montaj: Select a suitable indoor location for the emergency light, considering visibility and coverage requirements.
- Monte aparèy la:
- Surface Mount (versione a plafone): Secure the base of the fixture directly to the ceiling using appropriate screws and anchors.
- Recessed Mount (versione a incasso): Prepare a cutout in the ceiling according to the specified recessed dimensions (refer to Figure 4.1 and the dimensions table). Insert the fixture into the cutout and secure it with the provided clips or mounting hardware.
- IP66 Kit Version (versione con kit IP66): Follow specific instructions provided with the IP66 kit for enhanced weather and dust protection, typically involving additional sealing components.
- Fil elektrik: Connect the electrical supply wires to the fixture's terminals according to the wiring diagram provided with the product. Ensure all connections are secure and properly insulated.
- Final Asanble: Attach the diffuser or cover to the fixture.
- Tès: Restore power at the circuit breaker. The emergency light should illuminate briefly during initial power-up and then enter standby mode. Perform a functional test as described in the Operating Instructions.
4.2. Dimansyon (mm)
The following table provides key dimensions for the Beghelli BEG4103, as indicated in Figure 4.1. Dimensions may vary slightly depending on the specific version (surface, recessed, or with IP66 kit).
| Pouvwa (W) | L | B | H | L1 | B1 | H1 | L2 | B2 | H2 | H3 | DV schermo (m) | DV bandiera (m) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 8, 11, 24, 36 | 294 | 126 | 34 | 317 | 149 | 46 | 292 | 124 | 35 | 12 | 15 | 20 |
Note: Potenza indicativa per il confronto con apparecchi a tubo fluorescente (Indicative power for comparison with fluorescent tube fixtures). DV schermo refers to visibility distance for screen mounting, DV bandiera for flag mounting.
5. Operasyon Enstriksyon
The Beghelli BEG4103 emergency light operates automatically. When main power is present, the unit charges its internal battery (if applicable) and remains in standby mode. Upon a power failure, the light will automatically switch to emergency mode, providing illumination from its internal power source.
5.1. Functional Test (Touch Control)
The fixture features a "Tactile" control method, which typically refers to a test button. To perform a functional test:
- Ensure the main power supply to the fixture is active.
- Locate the touch-sensitive area or test button on the fixture.
- Briefly press or touch the control. The emergency light should illuminate for a short period (e.g., 3-5 seconds) to confirm battery and lamp fonksyonalite.
- Release the control. The light should return to standby mode.
Regular functional tests (e.g., monthly) are recommended to ensure the emergency light is operating correctly.
6. Antretyen
Proper maintenance ensures the longevity and reliable operation of your emergency light.
- Netwayaj: Netwaye deyò aparèy la detanzantan avèk yon twal mou, damp twal. Pa sèvi ak pwodui netwayaj abrazif oswa solvan. Asire w ke kouran an dekonekte anvan ou netwaye.
- Tcheke batri: For emergency lights with internal batteries, it is recommended to perform an annual discharge test. Disconnect the main power supply to the fixture and allow it to operate in emergency mode until the battery is fully discharged. Reconnect power and allow the battery to recharge for at least 24 hours. This helps maintain battery health.
- Poul: The integrated LED light source is designed for long life and is generally not user-replaceable. If the LEDs fail, the entire fixture may require replacement or professional servicing.
- Enspeksyon: Regularly inspect the fixture for any signs of physical damage, loose connections, or discoloration.
NAN. Depanaj
If you encounter issues with your Beghelli BEG4103, refer to the following troubleshooting guide:
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Limyè a pa limen lè kouran an etenntage. | No main power supply; Battery not charged; Faulty battery; Faulty LED driver. | Check circuit breaker. Ensure main power is restored. Allow 24 hours for battery to charge. If problem persists, contact qualified service personnel. |
| Light is dim in emergency mode. | Batri a pa chaje nèt; Batri a ap vye. | Allow sufficient time for battery to charge. Perform a full discharge/recharge cycle. If dimness persists, battery may need replacement by a qualified technician. |
| Light does not respond to touch control/test button. | No main power; Faulty control mechanism. | Ensure main power is active. If still unresponsive, contact qualified service personnel. |
For issues not listed above, or if solutions do not resolve the problem, contact Beghelli customer support or a qualified electrician.
8. Espesifikasyon
- Mak: Beghelli
- Modèl: BEG4103
- Kalite: Dirije Limyè Plafon Ijans
- Pouvwa: 11 Watts
- Sous limyè: dirije
- Materyèl: Glass, Polycarbonate (lamplonbraj)
- Style: Modèn
- Kalite montaj: Surface Mount, Recessed Mount (Ceiling Mount)
- Itilizasyon: Andedan kay la
- Sous pouvwa: Fil elektrik
- Metòd kontwòl: Touch (Tactile)
- Evalyasyon IP: IP40 (standard), IP66 (with specific kit)
- Etikèt enèji: A+
- Kantite anpoul: 1 (modil LED entegre)
- Koulè: Multicolore (refers to casing or indicator lights)
- Dimansyon: Refer to Section 4.2 and Figure 4.1 for detailed dimensions.
9. Garanti ak sipò
This Beghelli product is covered by the manufacturer's standard warranty. Please refer to the warranty card included with your product or visit the official Beghelli websit la pou wè tèm ak kondisyon garanti detaye yo.
For technical support, spare parts, or service inquiries, please contact your local Beghelli distributor or customer service. Ensure you have your product model number (BEG4103) and purchase information available when contacting support.