Broan-NuTone 353

Broan-NuTone 353 Gable Mount Attic and Garage Ventilation Fan User Manual

Modèl: 353

1. Pwodwi souview

The Broan-NuTone 353 Powered Attic and Garage Ventilation Fan is designed to prevent heat and moisture buildup in attics and garages. Proper ventilation helps maintain a cooler, drier environment, which can extend the lifespan of your roof and air conditioning system, while also reducing energy costs. This fan is suitable for ventilating one, two, or three-car garages, whether attached or detached from the home, effectively combating heat, humidity, and unwanted odors.

Karakteristik kle yo enkli:

  • Gable Mount Installation: Specifically designed for gable installation, requiring permanent electrical wiring and grounding. Extension cords must not be used.
  • Operasyon efikas: Delivers 760 Cubic Feet Per Minute (CFM) of airflow. Features a precision-balanced 14-inch metal blade for maximum air movement.
  • Konstriksyon dirab: Constructed with galvanized steel housing for enhanced strength and longevity.
  • Kontwòl otomatik: Equipped with an adjustable, built-in thermostat for automatic operation based on temperature.
  • Dimansyon: Housing measures 15 inches in diameter and 8 inches deep, with a 14-inch diameter steel blade.
Broan-NuTone 353 Gable Mount Attic and Garage Ventilation Fan

Image 1.1: Broan-NuTone 353 Gable Mount Attic and Garage Ventilation Fan. This image shows the complete fan unit, highlighting its robust construction and blade design.

2. Enfòmasyon sou Sekirite

AVÈTISMAN: Pou diminye risk pou dife, chòk elektrik, oswa blesi sou moun, obsève sa ki annapre yo:

  • Travay enstalasyon ak fil elektrik dwe fèt pa moun ki kalifye (yo) an akò ak tout kòd aplikab ak estanda, ki gen ladan kòd konstriksyon dife-rated ak estanda.
  • Toujou dekonekte kouran an nan panèl sèvis la anvan ou konekte fil elektrik yo oswa fè antretyen sou aparèy la.
  • This unit requires permanent electrical wiring and grounding. Do not use with an electrical extension cord.
  • This product is intended for gable installation only.
  • Avètisman Pwopozisyon 65 Kalifòni: Pwodui sa a ka genyen pwodui chimik Eta Kalifòni konnen ki lakòz kansè, domaj nesans, oswa lòt domaj repwodiktif.

3. Enstalasyon ak Enstalasyon

Proper installation is crucial for the efficient and safe operation of your Broan-NuTone 353 fan. This fan is designed for gable mounting. Ensure you have adequate soffit ventilation to allow for proper airflow.

3.1. Konsiderasyon Pre-Enstalasyon

  • Kondisyon pou vantilasyon: Calculate the required Cubic Feet Per Minute (CFM) for your attic or garage. A general guideline is to multiply the attic volume (Length x Width x Height) by 10 air changes per hour, then divide by 60 minutes/hour to get CFM. Ensure sufficient soffit vent area (approximately 0.48 square inches per CFM).
  • Fil elektrik: The fan requires permanent 120-volt AC electrical wiring and proper grounding. Consult a qualified electrician if you are unsure about electrical connections.
  • Kote montaj: Identify a suitable gable vent opening. The fan housing is 15 inches in diameter.
Broan Ventilation Calculator

Image 3.1: Ventilation Calculation Guide. This image provides a step-by-step guide to calculate the recommended CFM and minimum soffit vent area for effective ventilation.

3.2. Enstalasyon Vantilatè a

The fan is typically mounted to a wooden frame constructed around the gable vent opening. This frame provides a secure and stable base for the fan.

  1. Prepare the Mounting Board: Cut a piece of plywood (e.g., 21 inches square) to fit securely within the gable vent framing. Trace the fan's duct shape onto the plywood and cut out the opening.
  2. Pre-wire the Fan: Before mounting, connect 14/2 electrical wire to the fan's junction box. This makes wiring easier than doing it in a confined attic space.
  3. Secure the Fan to the Board: Center the fan on the prepared plywood board. Use 1/2-inch wood screws for the inner mounting holes and 1 1/2-inch wood screws for the outermost holes, ensuring they penetrate into the studs of the frame.
  4. Install the Assembly: Position the fan and plywood assembly into the gable vent opening. Secure it to the existing attic framing (e.g., 2x4s) using screws. Start with a few screws to support the unit, then add more to ensure it is very secure.
  5. Run Electrical Wiring: Route the electrical wire from the fan along the attic ridge to your power source (e.g., an existing outlet converted to a switch). Secure the wire with tacks every few feet.
  6. Konekte ak pouvwa: Wire the fan to a dedicated switch or power source according to local electrical codes.
Broan 353 Attic Ventilator Installation

Image 3.2: Gable Mount Fan Installation. This image illustrates the Broan 353 fan mounted within a wooden frame in a gable vent opening, showing the electrical connection box.

Broan 353 Fan Dimensions

Image 3.3: Fan Blade and Housing Dimensions. This image provides a visual reference for the fan's dimensions, including the 16-inch overall diameter and 14-inch blade.

4. Operasyon Enstriksyon

The Broan-NuTone 353 fan operates automatically via its built-in adjustable thermostat.

  1. Pouvwa sou: Ensure the fan is connected to a permanent power source and the wall switch (if installed) is in the "ON" position.
  2. Ajisteman tèmostat: The thermostat is located within the fan shroud. It controls when the fan activates based on the attic or garage temperature.
    • To adjust the temperature setting, access the thermostat and rotate the dial to your desired activation temperature.
    • Consider that the thermostat inside the shroud may register a slightly lower temperature than the overall attic temperature due to its proximity to the gable vent and airflow. You may need to set it lower than your desired attic temperature to achieve optimal operation.
    • Common settings range from 90°F to 110°F (32°C to 43°C).
  3. Operasyon otomatik: Once set, the fan will automatically turn on when the temperature at the thermostat reaches the set point and turn off when the temperature drops below it.

5. Antretyen

Regular maintenance helps ensure the longevity and efficient operation of your ventilation fan.

  • Enspeksyon anyèl: Annually, or more frequently in dusty environments, inspect the fan blades and motor for dust and debris buildup.
  • Netwayaj: Disconnect power to the fan at the circuit breaker before cleaning. Use a soft cloth or brush to gently remove any accumulated dust or dirt from the blades and motor housing. Do not use water or liquid cleaners directly on electrical components.
  • Tcheke pou obstak: Ensure the gable vent opening and fan blades are free from obstructions such as bird nests, leaves, or other debris.
  • Lubrifikasyon motè: The fan motor is typically permanently lubricated and does not require additional oiling. Refer to the motor's specific instructions if available.

NAN. Depanaj

If your Broan-NuTone 353 fan is not operating as expected, refer to the following common issues and solutions:

PwoblèmKòz posibSolisyon
Vantilatè a pa limen.
  • Pa gen pouvwa nan inite a.
  • Thermostat set too high or faulty.
  • Echèk motè.
  • Power junction box failure.
  • Tcheke disjonktè a ak switch miray la.
  • Adjust thermostat to a lower temperature. If still not working, thermostat may need replacement.
  • If motor does not spin freely by hand or does not start when power is directly applied (bypassing thermostat), the motor may need replacement.
  • Inspect wiring and junction box for loose connections or damage.
Fan is excessively noisy or vibrates.
  • Montaj ki lach.
  • Debris on fan blades.
  • BEARINGS motè chire.
  • Lack of vibration isolation.
  • Ensure all mounting screws are tight.
  • Disconnect power and clean fan blades.
  • If noise persists, motor may need replacement.
  • Consider adding rubber spacers or isolation pads between the fan's mounting ears and the wall to reduce transmitted noise.
Fan runs constantly.
  • Thermostat set too low or faulty.
  • Ambient temperature consistently above thermostat setting.
  • Adjust thermostat to a higher temperature.
  • Ensure the attic/garage temperature is actually dropping below the set point. If not, the fan is operating as intended.

7. Espesifikasyon

KarakteristikDetay
MakBroan-NuTone
Non modèl353
Kalite aliyeGable Mount
Kapasite Flow Air760 CFM (pye kib pou chak minit)
Voltage120 Volts
Wattage60 wat
Vitès1030 RPM
Nivo bri14.4 Desibèl
Dimansyon pwodwi (D x W x H)15"D x 1"W x 8"H (Housing)
Dyamèt lam14 pous
MateryèlGalvanized Steel (Housing), Metal (Blade)
Karakteristik espesyalAdjustable Built-in Thermostat
Sous pouvwaAC
Pwa atik11.1 liv
UPC026715001538

8. Garanti ak sipò

For warranty information, technical support, or to purchase replacement parts, please contact Broan-NuTone customer service or visit their official websit la. Kenbe resi acha ou kòm prèv acha pou reklamasyon garanti.

Ofisyèl Broan-NuTone Websit: www.broan-nutone.com

© 2024 Broan-NuTone. Tout dwa rezève.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.